TP48200A-DT19C1, TP48200A-DT19C2,
TP48200A-HT19C1, TP48200A-HT19C2 Outdoor
Power System
User Manual
(7) Handle
(10) LCD
Indicators
Table 2-2 SMU02B indicator description
Name
Run indicator
Minor alarm
indicator
Major alarm
indicator
Buttons
Table 2-3 SMU02B button description
Button
Issue 02 (2019-02-26)
port is protected by a
security mechanism.)
(8) Locking latch
Color
Green
Yellow
Red
Name
Description
Up
Go to the previous menu item or select a parameter value.
Hold down
parameter.
Down
Go to the next menu item or select a parameter value.
Hold down
parameter.
Back
Return to the previous menu without saving the settings.
Copyright © Huawei Technologies Co., Ltd.
(9) FE port
Status
Description
The SMU is faulty or has no
Off
DC input.
Blinking at 0.5
The SMU is running properly
Hz
and communicating with the
host.
The SMU is running properly
Blinking at 4 Hz
but is not communicating
with the host.
Off
No minor or warning alarm
has been generated.
Steady on
A minor or warning alarm
has been generated.
Off
No critical or major alarm
has been generated.
A critical or major alarm has
Steady on
been generated.
to quickly adjust the value of a selected
to quickly adjust the value of a selected
2 Components
16