Rinse Station Troubleshooting - Taylor SB25 Service Manual

Blended ice machine
Hide thumbs Also See for SB25:
Table of Contents

Advertisement

Rinse Station Troubleshooting

PROBLEM
Unit will not rinse.
Blender pitcher is not being rinsed
completely.
Blender pitcher is not being rinsed
completely.
Water is leaking from the unit.
Unit is not draining.
Model SB25
POSSIBLE CAUSE
The power switch is in the OFF
position.
The power plug is not inserted
into the power jack.
The DC converter is not plugged
into the wall outlet.
The DC converter is not
providing 24 volts.
The reed switch(es) is not in
position or is defective.
One or both actuators are
missing or missing a magnet.
The rinse PCB is defective.
The water line at the back of the
unit is not connected.
The water line is kinked.
Cold water is being used for
rinsing.
The rinse cycle is not long
enough.
Low water pressure in the store.
Poor fitting/hose connection.
The hose is cracked.
Broken fitting.
The water manifold is defective.
The drain line is kinked.
There is no air gap between the
drain line and the drain.
The drain line is clogged.
41
REMEDY
Place the power switch in the ON
position.
Check/correct the connection at
the rear of the unit.
Check/correct the connection at
the outlet.
Check the output of the
converter.
Check position of reed switch. It
should be fully inserted into the
threads. Replace if necessary.
Replace, if necessary.
Evaluate PCB and replace if
necessary.
Connect the water line.
Straighten the water line.
Use warm water to aid in the
rinsing process.
Adjust the cycle time on the Rinse
PCB.
Inform the store.
Check all visible fittings and
ensure all hoses are fitted into
the fittings properly.
Replace the hose if necessary.
Replace the fitting if necessary.
Repair with service parts; replace
if necessary.
Straighten the drain line.
Provide air gap.
Unclog the drain line.
Troubleshooting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents