General Repairs

IMPORTANT!
DO NOT attempt any interior repairs
until the following steps are completed. Failure
to follow these instructions may result in personal
injury or death from electrical shock or from
hazardous moving parts, as well as poor
performance or damage to the unit.
1.
Disconnect the main power supply to the unit.
2.
Disconnect the power cord at the plug.
3.
Remove the ice hopper.
(Note: Remove the ice before removing the ice
hopper.)
4.
Remove the side panels.
5.
Remove the drive board cover.
6.
Remove the water and cane lines.
Wait 30 seconds after disconnecting power
before removing the drive board cover.
Electrostatic Discharge Protection
Electrostatic Discharge (ESD) is the rapid discharge
of static electricity from one conductor to another of
a different potential.
An electrostatic discharge can damage integrated
circuits found in computer and communications
equipment. Follow instructions where noted.
Model SB25
Ice Hopper
______________________________
The ice hopper is the container for the ice cubes that
are consumed in the shaving process. The hopper
and lid have an integral magnetic mechanism that
triggers a safety switch which allows system
operation only when the hopper and lid are installed
correctly.
Disassembly
Step 1
Remove the hopper cover.
Step 2
Using a scoop, carefully remove the ice from the
hopper.
WARNING: The shaver blade is very
sharp. Caution must be used when working in or
near the shaver assembly. Failure to follow this
instruction may result in personal injury from blade
contact.
Step 3
Install the hopper cover and run the manual blend
cycle until all remaining ice is dispensed.
Step 4
Turn off the power switch and unplug the
power cord.
Step 5
Remove the hopper and hopper cover.
17