Blender Pitcher Rinse Station Repairs

Rinse Duration Settings
______________________________
The rinse duration is adjustable to 5, 7, 9, or 12
seconds. Adjust the rinse time by using the rotary
dip switch on the control PCB located under the
bottom cover of the unit. Note the dip switch settings
listed in the table below.
Figure 42
Water Usage (gallons)
Based on Inlet Pressure & Rinse Time Settings
Incoming Water Pressure
Dip
Rinse
Switch
Times
Setting
0
5 seconds
0.29 gal 0.33 gal 0.41 gal
1
7 seconds
0.41 gal 0.47 gal 0.57 gal
2
9 seconds
0.52 gal 0.60 gal 0.74 gal
3
12 seconds 0.69 gal 0.80 gal 0.98 gal
Rinse Station Triggers
______________________________
The Rinse Station detects the placement of the
blender pitcher on the rinse station pitcher platform.
If the pitcher triggers are not working properly, an
adjustment to the reed switches may be necessary.
The main power supply(s) to the unit
must be disconnected prior to performing any
installation, maintenance, or repairs. Failure to
follow this instruction may result in personal injury or
death from electrical shock or hazardous moving
Controls and Systems
30 psi
40 psi
60 psi
parts as well as poor performance or damage to the
unit.
1.
Turn off the main power to the unit.
2.
Disconnect the water supply at the quick
connect fitting.
3.
Remove the front pan assembly.
4.
Remove the bottom cover by removing the
screws.
5.
Install a jumper on P1 to put the drive board
into the Test Mode. This will allow the triggers
to be tested individually.
6.
Replace the front pan.
7.
Place the main power switch in the ON position.
8.
Test the triggers separately.
32
Figure 43
Figure 44
Model SB25