Texmate Tiger 320 Series User's Manual Supplement

Texmate Tiger 320 Series User's Manual Supplement

Linearizing
Hide thumbs Also See for Tiger 320 Series:
Table of Contents

Advertisement

T T i i g g e e r r 3 3 2 2 0 0 S S e e r r i i e e s s
Associated Documents
The following documents must be read
together with this supplement:
Relevant Tiger 320 Series User Manual
The user manual provides general informa-
tion on the relevant Tiger 320 Series meter.
Tiger 320 Series Programming Code Sheet
The programming code sheet provides all
meter programming codes including set-
point programming codes.
Programming Tip
This document has been written
using a DI-50 7-segment, 5-digit
display meter. When program-
ming meters with other display
options, some display readings
may vary to the diagrams shown.
Note
It is assumed that you are famil-
iar with the Programming
Conventions used throughout
the range of Texmate Tiger 320
Series literature as described in
the user manual.
•Linearizing Supplement (NZ207)
This document is designed to supplement the information described in
the Tiger 320 Series User Manual. It covers the meter's Linearizing
Functions.
Technical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Linearization Using 32 Flexible Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Linearization Table Setup Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Linearization Configuration Programming Codes . . . . . . . . . . . . . . . . . . . . .7
Linearization Table Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Code 1 - Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Code 3 - Non-preconfigured Linearization for CH1 . . . . . . . . . . . . . . . . . .11
Code 4 - Linearization for Channel 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Code 5 - Linearization for Channel 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Code 6 - Linearization for Channel 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Code 7 - Linearization for Result of CH1 & CH2 . . . . . . . . . . . . . . . . . . . .13
Linearization Programming Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Application Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Application Example - Manual Setup Mode . . . . . . . . . . . . . . . . . . . . . . .16
Application Example - Auto Setup Mode . . . . . . . . . . . . . . . . . . . . . . . . . .17
Application Example - Manual Setup Mode . . . . . . . . . . . . . . . . . . . . . . .18
Example Programming Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Application Example - Auto Setup Mode . . . . . . . . . . . . . . . . . . . . . . . . . .19
Two-point Calibration Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Apply a Linearization Table to a Channel Procedure . . . . . . . . . . . . . . . . . .26
List of Figures
Figure 1 - Non-linearized Sensor Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Figure 2 - Linearized Sensor Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Figure 3 - Linearized Sensor Output Showing Flexible Points . . . . . . . . . . . . . . . . . . . . .3
Figure 4 - Setup Modes Flow Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Figure 5 - Programming Code List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Figure 6 - Linearization Table Date Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Figure 7 - Linearize Yacht Fuel Tank Application Example . . . . . . . . . . . . . . . . . . . . . .15
Figure 9 - Linearization using the Auto Setup Mode . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
LINEARIZING SUPPLEMENT
Contents
Contents
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tiger 320 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Texmate Tiger 320 Series

  • Page 1: Table Of Contents

    T T i i g g e e r r 3 3 2 2 0 0 S S e e r r i i e e s s LINEARIZING SUPPLEMENT This document is designed to supplement the information described in Associated Documents the Tiger 320 Series User Manual. It covers the meter’s Linearizing Functions. The following documents must be read together with this supplement:...
  • Page 2 Meter – Controller The term meter, as used throughout this document, is a generic term for all Tiger 320 Series sig- nal processors and controllers Page 2 Texmate Inc.
  • Page 3: Technical Description

    36 mV Figure 3 – Linearized Sensor Output Showing Flexible Points Tiger 320 Series meters provide up to four independently programmable, flexible 32-point linearization tables, giving accurate results over the entire scaled range. Each linearization table can be assigned to more than one channel.
  • Page 4: Linearization Table Setup Modes

    Linearizing Standard Temperature Sensors cause inaccurate results. The Tiger 320 Series meter software has been pre-configured with the following standard thermocouple and RTD linearization tables stored in memory for easy selection. As the defined reference data for the tables has been pre-configured and stored in the meter, the...
  • Page 5: Figure 4 - Setup Modes Flow Diagram

    Note, 100 Ω and 1000 Ω RTDs have the same linearization table, but require 100 or 1000 Ω RTD input modules installed in the meter respectively. Linearization Setup Modes Tiger 320 Series meters provide three modes to configure a linearization table: • Auto Setup Mode.
  • Page 6 RTDs A temperature simulator is required to provide a 32 °F reference for a type 385 RTD before the selected RTD can be calibrated. Page 6 Texmate Inc. Tel. (760) 598-9899 • www.texmate.com •Linearizing Supplement (NZ207)
  • Page 7: Linearization Configuration Programming Codes

    Then press the button at the same Prog. time to exit. Figure 5 – Programming Code List •Linearizing Supplement (NZ207) Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com Page 7...
  • Page 8: Linearization Table Settings

    3 Totalizer Settings Mode 4 Setup 32-point Linearization Tables buttons to enter buttons to enter 5 Scale Analog Output LOW/HIGH (zero/span) input point number 32 output point number 32 Display Readings Page 8 Texmate Inc. Tel. (760) 598-9899 • www.texmate.com •Linearizing Supplement (NZ207)
  • Page 9: Code 1 - Configuration Settings

    • CH2 in Code 4, 3rd digit. • CH3 in Code 5, 1st digit. • CH4 in Code 6, 1st digit. • RESULT in Code 7, 2nd digit. •Linearizing Supplement (NZ207) Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com Page 9...
  • Page 10: Code 2 - Standard Thermocouple Or Rtd Linearization For Ch1

    4 Output Register 5 5 Output Register 6 6 Output Register 7 7 Smart Input Module Setup. See Note 7. Note 7: Only available with selected input modules. Page 10 Texmate Inc. Tel. (760) 598-9899 • www.texmate.com •Linearizing Supplement (NZ207) •Linearizing Supplement (NZ207)
  • Page 11: Code 3 - Non-Preconfigured Linearization For Ch1

    5 Period - 999.99 ms (10 µs resolution) 6 Up/Down Counter with Prescaler 7 Set Prescaler buttons to set prescale values from 1 to 65535 counts •Linearizing Supplement (NZ207) •Linearizing Supplement (NZ207) •Linearizing Supplement (NZ207) Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com Page 11...
  • Page 12: Code 5 - Linearization For Channel 3

    To apply a non-preconfigured linearization Table 4 to Channel 4 in a meter with more than 32 kilobits of memory, select 3 in the 1st digit in Code 6. Page 12 Texmate Inc. Tel. (760) 598-9899 • www.texmate.com •Linearizing Supplement (NZ207)
  • Page 13: Code 7 - Linearization For Result Of Ch1 & Ch2

    The selected table is not available if CH2, CH3, or CH4 is operating in the analog mode. CH1 must be set to Voltage, Current in Code 2 [X0X]. See Note 5 7 – •Linearizing Supplement (NZ207) Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com Page 13...
  • Page 14: Linearization Programming Sequence

    Initial Setup Procedures Product Validation Checks Carry out all product validation checks described in the Tiger 320 Series user manual. For a set of product validation checks, see Product Validation Checks in the relevant Tiger 320 Series user manual.
  • Page 15: Application Examples

    Texmate installed a Tiger 320 Series DI-50 meter and connected it to the level sensor. The meter is calibrated using the level sensor to provide an input related to the volume of the tank.
  • Page 16: Application Example - Manual Setup Mode

    100.0 35.7 bottom of the tank. 200.0 76.4 300.0 122.2 400.0 173.1 800.0 436.0 1200.0 832.0 Page 16 Texmate Inc. Tel. (760) 598-9899 • www.texmate.com •Linearizing Supplement (NZ207)
  • Page 17: Application Example - Auto Setup Mode

    Note that the first input/output point is at the bottom of the tank and is 0. The remaining 31 points are equal increments of 26 liters from the metering pump, bringing the total to 832 liters. •Linearizing Supplement (NZ207) Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com Page 17...
  • Page 18: Application Example - Manual Setup Mode

    Set Decimal Point for Channel 1 in Code 1 Enter Code 1 and set to [X61]. In the Display Format Mode, set the decimal point for dis- play resolution to tenths (0.1). For detailed Display Format Mode procedures, see the relevant Tiger 320 Series user manual. Page 18 Texmate Inc.
  • Page 19: Application Example - Auto Setup Mode

    • Setting the 3rd digit to 2 selects Table 2 as the linearization curve for CH2 input signal. For detailed measurement task procedures, see the relevant Tiger 320 Series user manual. Calibrate Channel 2 in the Calibration Mode Calibrate CH2 using the output from the level sensor: •...
  • Page 20: Application Example - Standard Temperature Sensors

    Enter Code 1 and set to [X61]. In the Display Format Mode, set the decimal point for dis- play resolution to tenths (0.1). For detailed Display Format Mode procedures, see the relevant Tiger 320 Series user manual. Application Example – Standard Temperature Sensors...
  • Page 21: Two-Point Calibration Procedure

    Step TEXMATE Example Prog. Step 6 Prog. Set the reading for zero END HERE Press END HERE load into the meter Operational Display and enter the Span Mode •Linearizing Supplement (NZ207) Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com Page 21...
  • Page 22: Configure Linearization Table Settings Procedure For Manual Mode

    Save the manual mode Press Press Save the serial Table Setup Procedures setting. Enter the Table number. Enter the continued at Step 13 Number setting menu first Input Point. Page 22 Texmate Inc. Tel. (760) 598-9899 • www.texmate.com •Linearizing Supplement (NZ207)
  • Page 23 Enter Output Point 2 TEXMATE Operational Display setting menu TEXMATE Prog. To Step TEXMATE Prog. Prog. Step 19 END HERE END HERE Set output point 2 to 357 •Linearizing Supplement (NZ207) Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com Page 23...
  • Page 24: Configure Linearization Table Settings Procedure For Auto Mode

    Save the auto mode Press Press Save the serial Table Setup Procedures setting. Enter the Table number. Enter the continued at Step 13 Number setting menu first Input Point. Page 24 Texmate Inc. Tel. (760) 598-9899 • www.texmate.com •Linearizing Supplement (NZ207)
  • Page 25 TEXMATE Operational Display Operational Display Example TEXMATE To Step Prog. Step 18 Press Prog. Save output point 3. Enter output point 4 END HERE END HERE setting menu •Linearizing Supplement (NZ207) Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com Page 25...
  • Page 26: Apply A Linearization Table To A Channel Procedure

    Operational Display time Operational Display TEXMATE Press at same Prog. Step 6 time Enter the Main Press at same Programming Mode time END HERE END HERE Page 26 Texmate Inc. Tel. (760) 598-9899 • www.texmate.com •Linearizing Supplement (NZ207)
  • Page 27: Selecting And Calibrating An S Type Thermocouple Procedure

    Press at same Programming Mode Save the SPAN input using K Type Thermocouple time signal setting and return continued on next page (Step 13) to the calibration mode •Linearizing Supplement (NZ207) Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com Page 27...
  • Page 28 Step 19 Type B Save the offset setting. Press continued on next page Type N Enter the scale factor Save Code 2 setting (Step 27) setting menu – Page 28 Texmate Inc. Tel. (760) 598-9899 • www.texmate.com •Linearizing Supplement (NZ207)
  • Page 29 Step 28 Calibrate the S type Press Save the scale factor Thermocouple using setting. Enter the Two-point Calibration Calibration Mode Procedure on Page 21 END HERE END HERE •Linearizing Supplement (NZ207) Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com Page 29...
  • Page 30 This page intentionally left blank Page 30 Texmate Inc. Tel. (760) 598-9899 • www.texmate.com •Linearizing Supplement (NZ207)
  • Page 31: Linearizing Supplement (Nz207) Texmate, Inc. Tel. (760) 598-9899 • Www.texmate.com

    This page intentionally left blank •Linearizing Supplement (NZ207) Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com Page 31...
  • Page 32 Texmate has facilities in the USA, Japan, New Zealand, Taiwan, and Thailand. We also have authorized distributors throughout the USA and in 28 other countries. 1934 Kellogg Ave.,Carlsbad, CA 92008 995 Park Center Drive • Vista, CA 92083-8397 For ordering info call: ..1-800-TEXMATE (1-800-839-6283) For tech assistance call: .

Table of Contents