Section 5 Trouble Shooting - Del ozone Solar Eclipse Installation & Operation Manual

Ozone + uv sanitation system
Hide thumbs Also See for Solar Eclipse:
Table of Contents

Advertisement

CAUTION: Follow the directions for use and
handling of muriatic acid on the acid bottle
label, being careful to protect your eyes, wear
rubber gloves, and avoid breathing acid fumes.
NOTE: DO NOT USE ABRASIVE CLEANERS
as they can scratch the high quality quartz
glass. If lime or hardwater calcium deposits are
encountered, use household tub and shower
lime removal.
5. After cleaning the quartz Tube, wash it off and
wipe dry. Inspect the quartz Tube for cracks.
Replace if cracks are found.
6. Make sure the inside of the quartz Tube is dry
before replacing the UV Lamp(s).
Note: DAMAGES CAUSED BY BROkEN
qUARTz TUBES ARE NOT COVERED
UNDER YOUR LIMITED WARRANTY.
4D-3 Quartz Tube Installation
1. Place the Sealing Ring on the quartz Tube 3/8
in. (9.5 mm) from the open end.
2. Insert the quartz Tube into the UV Reactor
carefully until it seats in the bottom of the UV
Reactor.
Note: The quartz Tube will rest on a spring
in the bottom of the UV Reactor. Gently press
the quartz Tube downward and feel for the
spring to push back to confirm that it is properly
seated.
3. Place the Compression Washers on the quartz
Tube so they sit on the Sealing quad Ring.
4. Screw the Compression Nut into the threads till
it is finger tight. DO NOT OVERTIGHTEN.
5. Turn the circulation pump ON and check the
quartz Tube seal for leaks.
6. Correct any leak found by carefully tightening
the Compression Nut one turn. If the leak
persists, remove the Compression Nut,
Compression Washers and the Sealing
Ring. Inspect all components and replace if
necessary.
7. Re-install the Sealing Ring, Compression
Washers, and Compression Nut and check the
unit for leaks again.
8. Turn the circulation pump OFF once you have
confirmed that the quartz Tube is not leaking.
4D-4 Re-installing the UV Lamp(s)
Make sure to handle the lamp as described in
section 4D-1.
1. TURN OFF YOUR PUMP IF YOU HAVE NOT
DONE SO.
2. Slowly lower the UV Lamp down into the quartz
Tube until it is seated in the bottom of the tube.
Solar Eclipse Installation & Operations Manual
3. Connect the Lamp Connector Plug to the pins
on the lamp.
NOTE: Do not force the Lamp Connector Plug
onto the pins. If force is needed, it means that
the components are misaligned.
NOTE: To replace a UV Lamp, follow only
Sections 4D-1 and 4D-4
ENVIRONMENTAL NOTICE - Hg-Lamp
CONTAINS MERCURY. Manage in accordance
with disposal laws. See: www.lamprecycle.org

SECTION 5 Trouble Shooting

knowledge of electrical applications is required
for trouble shooting. Contact a certified electrician
if you are unsure of your ability to service the
equipment. Improper servicing will void generator
warranty. If any condition persists contact DEL
Technical Support (see Section 6A).
Symptom: Green Indicator not lit when pool
system is on.
1. No power to the Solar Eclipse from the Power
Source:
a. Check circuit breaker at the power
distribution box.
b. Check for loose connections or wiring
breaks in the lines leading to the Terminal
Block.
c. Fuse in the unit has blown and needs to be
replaced. Fuse is an AGC-1 (1 amp ,1/4" x
1.25" long, glass fuse).
d. Indicator lights have burnt out.
Symptom: Red Indicator will not go out.
1. Insufficient flow through Solar Eclipse.
a. Verify that pump is running properly and
that filter and skimmers are clean.
b. Clear any blockages in return line.
Symptom: Green Ozone Module Light is not
illuminated when unit is running.
1. This means that the power supply of that
specific ozone module is no longer drawing
power and needs to be replaced. Refer to
Section 4C-2 for instructions on how to replace
the corresponding ozone module.