DIAGNOSTIC STATUS CODES
TRANSISTOR PUMP CONTROL
PUMP
DESCRIPTION OF STATUS
STATUS CODE
"SPEED 3" switch closed with the key
-103
turned off.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Pump
"SPEED 3" switch is closed or shorted
Controller
to battery negative.
·
PUMP
DESCRIPTION OF STATUS
STATUS CODE
"SPEED 4" switch closed with the key
-104
turned off.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Pump
"SPEED 4" switch is closed or shorted
Controller
to battery negative.
·
CORRECTIVE ACTIONS
Verify connections at P20 and
Battery negative. Replace switch,
if necessary.
CORRECTIVE ACTIONS
Verify connections at P21 and
Battery negative. Replace switch,
if necessary
.
CAUSE OF STATUS INDICATION
This status code will be displayed when the "SPEED
3" switch closes while the key switch is turned off.
TROUBLE-SHOOTING DIAGRAM
7
12
19
20
21
53
*
*
BATT
NEG
CAUSE OF STATUS INDICATION
This status code will be displayed when the "SPEED
4" switch closes while the key switch is turned off.
TROUBLE-SHOOTING DIAGRAM
7
12
19
20
21
53
*
*
BATT
NEG