Setup Function Procedures; Setup Mode; Status Code Scrolling - GE SX Series Installation And Operation Manual

Transistor control separately excited (sx) transistorized traction motor control and series pump motor control
Table of Contents

Advertisement

ADJUSTABLE FEATURES
SX TRANSISTOR CONTROLS
Section 5.3 Set-up Function Procedures
With the Handset connected, hold down the CONT key and
turn on the key switch. This will place you in the set-up
mode, ready to monitor or adjust control function settings.
NOTE: The term "Push" means to depress key for
approximately one second.
Section 5.3.1 Setup Mode
SET-UP MODE
DISPLAY
ACTION
SHOWS
Hold Down CONT
8 8 8 8
And Turn On Key
U 0 0 5
Push Function Number
After One Second
0 8 5
Time Delay
0 8 5
Push CONT
Change Value With
125
Adjustment Knob
125
Push STORE
8 8 8 8
Push ESC
At this point, another function can be monitored/changed
by pushing another function number, or the vehicle can be
placed in the run mode by holding the ESC key down for
one second or longer. The display will return to either the
diagnostics mode, the BDI display, or a blank display (if
BDI is not used and there are no fault codes). The vehicle
can now be operated with the Handset connected, or the
Handset can be disconnected before operation.
NOTE: You can return to the segment check mode at any
time, by holding down the ESC key until 8888 appears in
the display.
Section 5.3.2 Status Code Scrolling
The SX family of controllers furnishes a function register
that contains the last 16 "stored status codes" that shut
down vehicle operation (a PMT type fault that is reset by
cycling the key switch) and the battery state of charge
REMARKS
Segment Check
Displayed
Selected Function No.
Is Displayed
Stored Value For The
Function Is Displayed
Display Value
Will Blink
Value Changes
While Blinking
New Value Stored And
Blinking Stops
Segment Check
Displayed
reading at the time the fault occurred. The first of the 16
status codes will be overwritten each time a new status
code occurs. This stored status code register can be
cleared from memory by using the Handset.
ACCESSING STORED STATUS CODES
WITH GE HANDSET
Key Switch Off
Push ESC and CONT
At The Same Time
Release ESC and CONT
Key
Status Code Displayed
Push CONT Key
Displays Battery
State-Of-Charge When
Fault Occurred
Push CONT Key
Display Hourmeter Reading
When Fault Occurred
Push CONT Key
Section 5.3.3 SX Family Handset, Plug
Connections and Outline Drawing
"Y" Plug
Handset Cable Part Number - 325B1002G1
55
Page
Hold Both the
Push ESC to
ESC and CONT
Erase Stored
Keys Down to
Data
Erase All 16
Stored Codes
Push ESC to
Erase Stored
Data
Push ESC to
Erase Stored
Data
Revised May 2003

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents