Advertisement

上海麦兴仪器设备有限公司
www.imaxsun.com
IN 300 · IN 300/5
IMPAC-Pyrometer
Betriebsanleitung · Operation Manual
Proven Quality

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IN 300/5 and is the answer not in the manual?

Questions and answers

Summary of Contents for LumaSense IN 300/5

  • Page 1 上海麦兴仪器设备有限公司 www.imaxsun.com IN 300 · IN 300/5 IMPAC-Pyrometer Betriebsanleitung · Operation Manual Proven Quality...
  • Page 2: Table Of Contents

    IMPAC pyrometers IN 300 · IN 300/5 Contents General..........................14 Information about the operation manual ............... 14 Limit of liability and warranty................. 14 Terminology ......................14 Copyright ......................14 Disposal / decommissioning ................. 14 Technical data ........................15 Dimensions ......................15 Appropriate use ....................
  • Page 3: General

    LumaSense Technologies is not liable for any damages that arise from the use of any examples or processes mentioned in this manual or in case the content of this document should be incomplete or incorrect.
  • Page 4: Technical Data

    IMPAC pyrometers IN 300 · IN 300/5 Technical data Temperature ranges: IN 300: 0 ... 100°C (MB 1) 0 ... 200°C (MB 2) 30 ... 230°C (MB 2.3) -20 ... 300°C (MB 3) 0 ... 500°C (MB 5) 0 ... 600°C...
  • Page 5: Appropriate Use

    The IN 300 is a stationary pyrometer for non-contact temperature measurement of non-metallic surfaces or painted, coated or anodized metals. The IN 300/5 is a stationary pyrometer for non-contact temperature measurement of glass sur- faces and quartz surfaces. Scope of delivery Instrument, works certificate, user manual.
  • Page 6: Accessories

    IMPAC pyrometers IN 300 · IN 300/5 Example for wiring using a digital display with integrated power supply: 230 V white Digital display brown with built-in °C 2-wire supply Shield (black) 4 ... 20 mA Controller Wiring white 24 V...
  • Page 7: Optics

    IMPAC pyrometers IN 300 · IN 300/5 Optics The pyrometers are equipped ex works with one of the following optics. These lenses are focusing to certain distances, i.e. in these distances each lens achieves its smallest spot size in relation to the measuring distance.
  • Page 8: Emissivity

    IMPAC pyrometers IN 300 · IN 300/5 Emissivity For a correct measurement it is necessary to adjust the emissivity ε. This emissivity is the relation- ship between the emission of a real object and the emission of a black body radiation source (this is an object which absorbs all incoming rays and has an emissivity of 100%) at the same tempera- ture.
  • Page 9: Transport, Packaging, Storage

    IMPAC pyrometers IN 300 · IN 300/5 Transport, packaging, storage The instrument can be damaged or destroyed if shipped incorrectly. To transport or store the instrument, please use the original box or a box padded with sufficient shock-absorbing material. For storage in humid areas or shipment overseas, the device should be placed in welded foil (ideally along with silica gel) to protect it from humidity.
  • Page 10: Trouble Shooting

    IMPAC pyrometers IN 300 · IN 300/5 Trouble shooting Before sending the pyrometer for repair, try to find the error and to solve the problem with the help of the following list. Temperature indication too low  Incorrect alignment of the pyrometer to the object ...
  • Page 11: Reference Numbers

    IMPAC pyrometers IN 300 · IN 300/5 Reference numbers 10.1 Reference numbers instruments 3 856 310 IN 300, 0 ... 100°C (MB 1) 3 856 320 IN 300, 0 ... 200°C (MB 2) 3 856 230 IN 300, 30 ... 230°C (MB 2.3)

This manual is also suitable for:

In 300

Table of Contents