Parts supplied (all models):
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts
are included.
Parts needed: (not supplied with dryer)
Electric Cord and Plug
Vent clamps
Vent elbows and ductwork
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with dryers.
The kit should contain:
A UL listed 30-amp power supply cord, rated 240 volt
minimum. The cord should be type SRD or SRDT and be at
least 4 ft (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned
ends.
A UL listed strain relief.
Additional parts may be required, depending on your installation.
Check local codes. Check existing electrical supply and venting.
Read "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
4

LOCATION REQUIREMENTS

Select proper location for your dryer to improve performance
and minimize noise. Check code requirements. Some codes limit,
or do not permit, installation of the dryer in garages, closets,
mobile homes, or sleeping quarters. Contact your local building
inspector.
You will need:
A location that allows for proper exhaust installation. The
dryer must be exhausted to the outdoors. See "Venting
Requirements."
A floor that will support the dryer and a total weight (dryer
and load) of 90,7 kg (200 lbs). The combined weight of a
companion appliance should also be considered.
A level floor with maximum slope of 25 mm (1") under entire
dryer. If slope is greater than 25 mm (1"), install Extended
Dryer Feet Kit. Clothes may not tumble properly and models
with automatic sensor cycles may not operate correctly if
dryer is not level.
It is important to make sure the room has an adequate air
supply for drying operation. The operation of this appliance
may affect the operation of other appliances which take their
air supply for safe combustion from the same room.
Adequate ventilation must be provided to avoid a backflow
of gases into the room from appliances burning other
fuels, including open fires. If in doubt consult the appliance
manufacturers.
IMPORTANT: The dryer must not be installed or stored in an
area where it will be exposed to water and/or weather. Do not
operate your dryer at temperatures below 7°C (45°F). At lower
temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
Proper installation is your responsibility.