Error Messages
The unit might report any error message to notify the operator about any
incident or anomaly during the counting. This table shows a summary of
the possible error messages.
ERROR
MESSAGES
UV alarm
MG alarm
Chain Error
Double Note
DD alarm
Half error
Reset Unit
Hopper Sensor
error
Stacker Sensor
error
Count Sensor
R
Count Sensor
L
Note: If/When replacing fuses, make sure to use the same type and rating as the one that
came with the equipment.

4. Warning and Error Messages

POSSIBLE CAUSE
Suspicious UV feature
Suspicious MG feature
Two or more bills passed together
(partially overlap)
Two or more bills passed together
(one on top other)
Check the size of the bill (width)
Check for mutilated bill
Emergency stop is activated
Hopper sensor problem or bills in
the hopper
Stacker sensor problem or bills in
the stacker
Right counting sensor problem
Left counting sensor problem
- Remove the suspicious bill
- Consider reducing UV sensitivity
- Remove the suspicious bill
- Consider reducing MG sensitivity
- Adjust thickness adjustment knob
- Verify the bill's ftness quality
- Fan the bills
- Adjust thickness adjustment knob
- Consider reducing LEVEL sensitivity
- Verify the specifc bill
- Consider reducing DD sensitivity
- Remove the specifc bill
- Turn the unit OFF and ON again
- Clean the hopper sensor
- Contact technical support
- Clean the stacker sensor
- Contact technical support
- Clean the sensor
- Contact technical support
- Clean the sensor
- Contact technical support