Default LANE Configuration
Note
On the Cisco LightStream 1010 switch, the ATM address prefix is called the node ID. Prefixes must be 26
digits long. If you provide fewer than 26 digits, zeros are added to the right of the specified value to fill it to
26 digits. LANE prefixes must start with 39 or 47.
Note
If you do not save the configured value permanently, it will be lost when the switch is reset or powered off.
To display the current prefix on the Cisco LightStream 1010 switch, use the show network EXEC
command.
To set the ATM address prefix, use the following commands on the Cisco LightStream 1010 switch
beginning in global configuration mode:
SUMMARY STEPS
1. Switch(config)# atm address {atm_address | prefix... }
2. Switch(config)# exit
3. Switch# copy running-config startup-config
DETAILED STEPS
Command or Action
Step 1 Switch(config)# atm address {atm_address | prefix... }
Step 2 Switch(config)# exit
Step 3 Switch# copy running-config startup-config

Setting Up the Signalling PVC

You must set up the signalling PVC and the PVC that will communicate with the ILMI on the major ATM
interface of any Catalyst 5000 series switch that participates in LANE. Complete this task only once for a
major interface. You need not repeat this task on the same interface even though you might configure LESs
and clients on several of its subinterfaces.
To set up these PVCs, use the following commands beginning in global configuration mode:
SUMMARY STEPS
1. ATM(config)# interface atmslot/port
2. ATM(config)# atm pvcvcd vpi vci qsaal
3. ATM(config)# atm pvcvcd vpi vciilmi
DETAILED STEPS
Command or Action
Step 1 ATM(config)# interface atmslot/
port
10
Purpose
Specifies the major ATM interface and enters interface configuration mode.
Purpose
Sets the local node ID (prefix of the ATM address).
Exits global configuration mode.
Saves the configuration values permanently.