Table 12 — Fan Performance (English), 50TFQ008,009 — Vertical Discharge Units
AIRFLOW
0.2
(Cfm)
Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp
2200
503
0.50
585
2400
534
0.61
613
639
2600
565
0.74
2800
597
0.89
665
3000
629
1.06
694
3200
662
1.25
724
3400
696
1.46
756
3600
729
1.69
787
3800
763
1.95
819
LEGEND
Bhp
— Brake Horsepower
Rpm — Fan Wheel Speed, Revolutions per Minute
NOTES:
1. Boldface indicates field-supplied drive required.
2.
indicates field-supplied motor and drive required.
3. Maximum usable bhp is 2.40 with standard 1.5-hp motor. Exten-
sive motor and electrical testing on these units ensures that the
Table 13 — Fan Performance (English), 50TFQ012 — Vertical Discharge Units
AIRFLOW
0.2
(Cfm)
Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp
3000
532
0.64
605
3200
557
0.75
628
3400
583
0.88
651
3600
609
1.01
674
3800
535
1.16
698
4000
662
1.33
722
4200
689
1.52
746
4400
715
1.72
772
4600
742
1.94
797
4800
770
2.18
823
5000
797
2.44
849
LEGEND
Bhp
— Brake Horsepower
Rpm — Fan Wheel Speed, Revolutions per Minute
NOTES:
1. Boldface indicates field-supplied drive required.
2.
indicates field-supplied motor and drive required.
3. Maximum usable bhp is 2.90 with standard 2.0-hp motor. Exten-
sive motor and electrical testing on these units ensures that the
EXTERNAL STATIC PRESSURE (in. wg)
0.4
0.6
0.8
0.71
653
0.92
716
1.15
0.84
677
1.06
738
1.30
0.97
703
1.20
761
1.46
1.12
731
1.40
786
1.66
1.29
759
1.59
812
1.88
1.50
785
1.80
840
2.11
1.73
811
2.02
868
2.37
1.98
839
2.27
894
2.64
2.27
869
2.56
920
2.92
EXTERNAL STATIC PRESSURE (in. wg)
0.4
0.6
0.8
0.81
670
0.97
725
1.12
0.93
690
1.10
746
1.28
1.06
711
1.25
767
1.44
1.22
732
1.42
787
1.61
1.39
755
1.59
808
1.80
1.57
778
1.78
829
2.01
1.77
801
1.99
851
2.23
1.99
825
2.22
873
2.46
2.22
848
2.48
896
2.72
2.46
872
2.75
919
3.00
2.73
897
3.04
943
3.30
1.0
1.2
1.4
772
1.38
824
1.63
884 1.95
794
1.55
844
1.81
892 2.08
816
1.74
866
2.01
913 2.29
839
1.93
889
2.23
935 2.52
862
2.15
911
2.46
957 2.78 1000 3.09 1040 3.41
887
2.41
934
2.71
980 3.04 1022 3.38
914
2.69
959
3.00 1003 3.32
942
2.99
984
3.32
970
3.31
full horsepower range of the motor can be utilized with confi-
dence. Using your fan motors up to the brakepower ratings
shown will not result in nuisance tripping or premature motor
failure.
4. Use of field-supplied motor may affect wire sizing. Contact
Carrier representative to verify.
5. Values include losses for filters, unit casing, and wet coils.
6. Motor drive range is 620 to 880 rpm. All other rpm's will require a
field-supplied drive.
1.0
1.2
1.4
778
1.28
825
1.43
874 1.60
796
1.44
844
1.61
888 1.70
815
1.61
863
1.79
907 1.97
836
1.80
880
1.98
926 2.18
857
2.01
901
2.20
943 2.39
878
2.22
922
2.44
962 2.63 1003 2.84 1042 3.06 1078 3.26
898
2.45
943
2.69
983 2.91 1021 3.11 1060 3.34
919
2.71
963
2.94 1004 3.19 1042 3.41
940
2.98
984
3.22 1025 3.48
963
3.27
full horsepower range of the motor can be utilized with confi-
dence. Using your fan motors up to the brakepower ratings
shown will not result in nuisance tripping or premature motor
failure.
4. Use of field-supplied motor may affect wire sizing. Contact
Carrier representative to verify.
5. Values include losses for filters, unit casing, and wet coils.
6. Motor drive range is 690 to 900 rpm. All other rpm's will require a
field-supplied drive.
18
1.6
1.8
934 2.30
916 2.64 1019 3.09
944 2.40
987 2.76 1039 3.20
957 2.58 1004 2.91 1050 3.31
978 2.62 1019 3.13 1061 3.47
1.6
1.8
926 1.82
974 2.11 1012 2.36
934 1.94
988 2.18 1025 2.47
947 2.14
991 2.32 1038 2.57
966 2.36 1004 2.54 1045 2.74
985 2.60 1023 2.79 1059 2.98
2.0
2.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

50tfq00950tfq012

Table of Contents