• 2. CHANGING TURBULATOR, INJECTOR AND ELECTRODES
Remove the silicon hoses from the fan. They are connected to the protecting case's connection point on side of fan.
Remove the burner ventilation cap by unsnapping fixing screw (look, picture 2a)
Loosen and screw off the turbulator counter clockwise to reach the electrodes and injector easily ( turning clockwise tightens, turning counter
clockwise loosen) (pic.2b)
Use 11nr key for dismantling and mounting operations for cleaning or changing the injector.
Untighten the electrod stand connection screws which are placed under cast burner barrel for changing electrodes ( see pic. 2b).
Remove the cables of electrodes and remove the screws which are fixing electrodes to the stand and chance the electrodes. (See pic. 2b)