• 2. CHANGING TURBULATOR, INJECTOR AND ELECTRODES
•
Remove the silicon hoses from the fan. They are connected to the protecting case's connection point on side of fan.
•
Remove the burner ventilation cap by unsnapping fixing screw (look, picture 2a)
•
Loosen and screw off the turbulator counter clockwise to reach the electrodes and injector easily ( turning clockwise tightens, turning counter
clockwise loosen) (pic.2b)
•
Use 11nr key for dismantling and mounting operations for cleaning or changing the injector.
•
Untighten the electrod stand connection screws which are placed under cast burner barrel for changing electrodes ( see pic. 2b).
•
Remove the cables of electrodes and remove the screws which are fixing electrodes to the stand and chance the electrodes. (See pic. 2b)
19