ABB HD4/R Installation And Operating Instructions Manual page 14

Medium voltage products
Table of Contents

Advertisement

5.7.3 General specifications of fixed circuit-breakers
with rh lateral operating mechanisms for ABB UniMix switchgear (12 - 17.5 - 24 kV)
Circuit-breaker
Standards
Rated voltage
Rated insulation voltage
Withstand voltage at 50 Hz
Impulse withstand voltage
Rated frequency
Rated thermal current (40°C)
Rated duty breaking capacity
(symmetrical rated short-circuit current)
Short-time withstand current (3 s)
Making capacity
Sequence of operations
Opening time
Arcing time
Total break-time
Closing time
Overall dimensions
(maximum)
Weight
(3)
Absolute gas pressure (nominal duty value)
Application of PR521 protection device
Application of REF 601 protection device
Standardized dimensions table
Wiring diagram
Operating temperature
Tropicalization
Electromagnetic compatibility
increase the indicated weight by 20 kg for circuit-breakers with PR521 / REF 601 devices and 3 current sensors (15 kg only with 2 current sensors)
((1)
rated current of the current sensors (the PR521 device and the current sensors are available on request)
(2)
the REF 601 device and the current sensors are available on request. The rated current of the REF 601 must be set in the relay and must be compatible with the rated current of the
(3)
circuit-breaker. The rated current that can be set with CEI 0-16 is 80 A or 250 A. With the CEI 0-16 version of REF 601, the circuit-breaker is always supplied with 3 phase sensors
(Rogowsky coils) on the circuit-breaker itself, one 40/1 A closed-core toroidal TA and a -MU undervoltage release for relay-controlled opening
(4)
HD4/UniAir for Unit P1/F (unit with plug-in circuit-breaker)
HD4/UniAir-2R for Unit P1E/2R (unit with plug-in circuit-breaker on the supply and load sides)
(5)
HD4/UniAir-A for Unit P1/A (unit with fixed "upside-down" circuit-breaker)
(6)
HD4/UniAir-F for P1/F Unit (unit with fixed circuit-breaker without wheels and cabled to terminal box); the 12-17.5-24 kV types available are 630 A, 12.5 and 16 kA only
(7)
at 12 and 17.5 kV and at 630 A rated current, the rated short-time withstand current is 20 kA for 1 second
(8)
14
[O - 0.3s - CO - 15s - CO]
H
D
L
Pole center-distance [mm]
without relay / with PR521
IEC: 60068-2-30, 60721-2-1
HD4/UniMix 12
IEC 62271-100
CEI EN 62271-100
(dossier 7642)
Ur [kV]
12
Us [kV]
12
Ud (1 min) [kV]
28
Up [kV]
75
fr [Hz]
50-60
Ir [A]
630
Isc [kA]
12.5
16
20
25
12.5
Ik [kA]
16
20
25
Ip [kA]
31.5
40
50
63
[ms]
45
[ms]
10...15
[ms]
55...60
[ms]
80
H [mm]
734.5
L [mm]
393.5
D [mm]
1049
230
[kg]
103
[kPa]
380
In [A] 40 - 80 - 250 - 1250
TN 7366
1VCD003396
1VCD400017
1VCD400018
with REF 601
1VCD400114
1VCD400116
[°C]
- 5 ... + 40
IEC 62271-1
HD4/UniMix 17
17.5
17.5
38
95
50-60
630
12.5
16
20
(5)
12.5
16
20
31.5
40
50
45
10...15
55...60
80
734.5
393.5
1049
230
103
380
40 - 80 - 250 - 1250
(2)
(3)
(3)
TN 7366
(4)
(4)
1VCD003396
(5)
(5)
1VCD400017
(4)
(4)
1VCD400018
(5)
(5)
1VCD400114
(4)
(4)
1VCD400116
(5)
(5)
- 5 ... + 40
HD4/UniMix 24
24
24
50
125
50-60
630
12.5
16
20
12.5
16
20
31.5
40
50
45
10...15
55...60
80
734.5
393.5
1049
230
103
380
40 - 80 - 250 - 1250
(2)
(2)
(3)
TN 7366
(4)
1VCD003396
(5)
1VCD400017
(4)
1VCD400018
(5)
1VCD400114
(4)
1VCD400116
(5)
- 5 ... + 40

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd4/sHd4/uniairHd4/r-secHd4/unimix

Table of Contents