Psetup Command - Racal Instruments 1260-14C Manual

1260 vxi switching card, open collector digital i/o module
Table of Contents

Advertisement

PSETUP command

Module Specific Syntax 3-8
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
port that was last used to write a binary 10101101.
The command:
PD 1.0-4
would return the following data:
001. 1260-14C DIGITAL INPUT/OUTPUT MODULE<CR>
<LF>
001. 00:9F,7F,3F,1F<CR><LF>
001. 01:21,31,41,51<CR><LF>
001. 02:7AA6<CR><LF>
001. 04:10101101<CR><LF>
001.END<CR><LF>
Syntax:
PS[ETUP] <address>
<address>::= Module address of the 1260-14C (1-
12)
Description:
This command will cause the module to return the
condition of all the setup variables for the 1260-14C at the
specified module address. The following is a sample output from
a PSETUP command for a 1260-14C at module address 1,
showing the power-up default condition for the setup variables:
001. 1260-14C DIGITAL INPUT/OUTPUT MODULE
001. ENABLE
001. SYNC 0
001. BUSY POS
001. CLKIN POS
001. ARM OFF
001.END
Since the "ENABLE" command is not supported on
the 1260-14C, the "ENABLE" entry in the PSETUP
response is meaningless and should be ignored.
User Manual 1260-14C
NOTE

Advertisement

Table of Contents
loading

Table of Contents