Definition Of Commands; Pdataout Command - Racal Instruments 1260-14C Manual

1260 vxi switching card, open collector digital i/o module
Table of Contents

Advertisement

Definition of
Commands
PDATAOUT
Command
Module Specific Syntax 3-6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Write data may be in either decimal, hexadecimal, or binary
format. Non-decimal numbers must be preceded with "H"
for hex, or "B" for binary.
Syntax:
PD[ATAOUT] <address>[.<ports>][,<address>
[.<ports>],...]
<address>::= Module address of the 1260-14C (1-12)
<ports>::=
return data from. A single port is specified as a
decimal number from 0 to 11. A group of ports is
specified as two decimal numbers from 0 to 11
separated by a hyphen, (-), with the lower
numbered port to the left and the higher numbered
port to the right. For example, the command string
PD 1.3-5 would return values for ports 3, 4 and 5.
Description:
The PDATAOUT command will cause the module
specified by the logical address to return the data associated with
each requested port. The format of the return data is as follows:
<address>. 1260-14C DIGITAL INPUT/OUTPUT MODULE
where:
<address>::= A three digit module address. (001-012)
User Manual 1260-14C
One or more consecutive ports to
<CR><LF>
<address>. [<port>:
<data>,...]<CR><LF>
<address>.END<CR><LF>
<data>::=
From 0 to 256 pieces
of data in eitherdecimal, hexadecimal
or binary format.
<port>::=
A 2-digit number
specifying the port to associate with
the data that follows.