Troubleshooting  Tips  
 
No  output.  The  power  switch  is  on,  but  the  power  LED  is  off  and  tubes  do  not  light  up.  
•   AC  cable  makes  a  bad  connection  in  the  IEC  connector.  Please  check.  
•   Mains  fuse  is  broken.  Please  check.  
•   PTP™  (Power  Transformer  Protection)  protection  may  have  switched  off  the  power  transformer.  
If  so,  the  amplifier  will  switch  on  again  after  the  internal  temperature  of  the  power  transformer  
returns  to  normal.  Overheating  might  be  caused  by  higher  environment  temperature  than  normal  
or  heavy  use.  
 
No  output.  The  power  switch  is  on,  the  front  LED  is  green  and  tubes  do  light  up.  
•   Adaptive  Auto  Bias  Board  fuse  is  broken.  Please  check.  
 
No  output.  The  power  switch  is  on,  the  front  LED  is  red  and  LED  in  front  of  a  power  tube  MIGHT  light  up.  
TM
•   BTI
 circuit  has  switched  off  the  high  voltage  supply  to  the  power  output  tubes.    
This  can  happen  for  example,  when  one  (or  more)  output  tube(s)  draw(s)  significantly  more  
current  than  normal,  like  what  can  happen  when  a  loudspeaker  terminal  is  short-­circuited  with  the  
volume  turned  up.    
•   In  case  of  an  internal  output  tube  failure,  the  BTI™  circuit  understands  that  there  is  a  new  
situation  which  can  cause  harm  to  the  amplifier  or  the  loudspeaker,  and  the  high  voltage  power  
supply  to  the  output  tubes  is  interrupted  as  a  protective  measure.  The  front  LED  will  turn  red  and  
you  might  see  a  red  LED  in  front  of  one  or  more  power  tubes.  To  reset,  switch  the  amplifier's  
power  off  for  at  least  two  minutes,  then  switch  back  on.  Of  course,  this  should  only  be  done  after  
the  cause  of  the  failure  has  been  identified  and  resolved.  Switching  the  power  back  on  too  early  
can  fool  the  BTI
may  put  the  amp  back  into  protection  mode  again.  So  be  sure  to  give  it  enough  time  to  reset.  
 
Noise  or  hum  coming  from  one  channel  (eventually  when  you  change  your  volume  setting).  
•   Noisy  tube.  At  first  swap  the  two  inner  small  tubes  left  to  right.  If  noise  follows  the  tube  swap  then  
you  have  found  the  problem  tube.  If  noise  does  not  follow,  swap  the  next  set  of  two  small  tubes  
left  to  right,  eventually  the  next  set  in  case  your  amplifier  has  6  small  tubes.  
•   Possible  bad  output  tube.  Swap  the  output  tubes  in  pairs  from  right  to  left.  If  hum  follows  the  
swap,  swap  the  far  left  and  far  right  tubes.  If  the  hum  returns  to  the  original  problem  channel,  you  
have  found  the  problem  tube.  If  not,  swap  the  inside  output  tubes  left  to  right.  
 
Noise/distortion  coming  from  both  channels.  
•   Tubes  may  be  in  need  of  replacement.  
EvoLution  Series  
TM
 circuit  into  acting  as  though  the  problem  has  not  been  totally  resolved  and  it  
14  