Fuse  Protection  
 
Warning!  Fuses  are  safety  valves.  They  should  always  be  replaced  with  the  exact  same  value  and  type.    
Never  attempt  to  check  or  replace  a  fuse  while  the  amp  is  plugged  in.  Turn  it  off  and  unplug  the  AC  cord  
before  continuing.  Wait  10  minutes  to  let  tubes  cool  down  and  the  circuit  to  fully  discharge.  
black.  The  silver  screw  indicates  the  Live  AC  in  the  IEC  connector.  It  helps  with  the  "correct"  connection  
to  AC.  Nevertheless  always  check  the  AC  cable  by  measuring  as  not  every  AC  cable  is  constructed  the  
same  way.  
 
The  Adaptive  Auto  Bias  Board  is  protected  with  an  easily  accessible  Littelfuse  
213  315mA  fuse  located  next  to  the  on  /  off  power  switch  on  the  left  side  of  the  
Amplifier,  just  behind  the  front.  
 
Electronic  Protection  
 
The  PrimaLuna  EVO  Tube  Integrated  Amplifiers  are  equipped  with  Soft  Start™  and  come  with  an  
extensive  output  stage  protection  circuitry   with  +B  relay  to  protect  output  transformers,  resistors  and  high  
voltage  power  supply  in  case  a  tube  fails.    
 
The  board  also  comes  with  a  BTI™  circuit.  BTI™  stands  for  Bad  Tube  Indication  (by  the  change  of  front  
LED  to  red),  making  tube-­life  again  a  bit  easier.  The  BTI™  circuit  is  totally  inactive  during  normal  
operation.  However  when  one  (or  more)  output  tube(s)  draw(s)  significantly  more  current  than  normal  for  
a  couple  of  seconds,  such  as  when  a  loudspeaker  terminal  short-­circuits  with  volume  turned  up,  or  in  the  
case  of  an  output  tube  failure,  the  BTI™  circuit  "reads"  the  changes  as  a  potential  threat  and  as  a  
protective  measure,  interrupts  the  power  supply.  It  indicates,  by  the  led  in  front  of  the  power  tube,  which  
tube  might  be  bad.  To  reset,  simply  turn  the  power  off  and  after  two  minutes,  turn  back  on.  However,  
you  do  not  want  to  repower  the  unit  until  the  cause  of  the  failure  has  been  identified  and  resolved.  
Switching  the  power  back  on  too  early   also  can  fool  the  BTI  circuit  into  acting  as  though  the  problem  has  
not  been  totally  resolved  and  it  may  put  the  amp  back  into  protection  mode  again.  So  be  sure  to  give  it  
enough  time  to  reset!  
EvoLution  Series  
 
Mains  Fuse:  The  mains  fuse  is  located  on  the  rear  of  the  amplifier,  just  
below  the  power  cord  socket  (see  picture  on  the  left).  The  fuse  rating  is  1  x  
Littelfuse  213  Series  3.15A  Slow  Blow   5  x  20mm  fuse  for  100-­125VAC  and  
Littelfuse  213  Series  1.6A  Slow  Blow  5  x  20mm  fuse  for  200-­250VAC.  
Always  replace  with  the  same  type  and  value  fuse!  The  fuse  holder  can  be  
opened  using  a  small  slotted  flat  blade  screwdriver.    
 
The  IEC  connector  is  mounted  with  2  different  color  screws.  One  silver,  one  