J.
Mis-convergence
Adjust the "H. STAT" and
"V. STAT" user's controllers
to minimize the mis- con-
vergence.
3 colors asymmetry
Adjust the 6 pole
magnet
*
If
there
exist
some
mis-convergence
after
the Pots adjustment, try
to use some permalloy
sheets.
Horizontal
convergence
*
Try to adjust "H. STAT"
VR on side panel
*
*
No
Try to adjust the Pots on
the DY
Change the DY and read-
just
Yes
-43-
Yes
GDM-2036S
*
Refer to "Adjustment"
section.
Fig. 6-3-13 (Part I. P)
Go to "START" if there is
any trouble.
Vertical mis-convergence
*
Try to adjust "V. STAT
REF", "V. STAT TOP" and
"V. STAT BOTTOM" VRs
on "N" board.
Go to "Start" if there is
any trouble.