2.4.6 Analog Input
Enable or disable: interface data can be operated or acquired after enabling data center
Analog type: choose if you measure the voltage or current.
Measurement unit: voltage: V/mV/uV, current: A/mA/uA. The measurement unit will
influence the unit of " the corresponding voltage/current of top range " and " the
corresponding voltage/current of low range"
Corresponding voltage/current of top range: upper limit of voltage or current
True value of top range: the corresponding true data of upper limit voltage or current,
such as temperature, humidity, etc.
Corresponding voltage/current of low range: lower limit voltage or current
True value of low range: the corresponding true data of lower limit voltage or current,
such as temperature, humidity, etc.
For example:
Corresponding voltage/current of top range=5V, true value of top range=5℃