9 8 Error messages

9.1 8.1 LCD Display

The LCD HMI in case of errors or malfunctioning is able to display specific error/fault messages to help the user in identifying the
problem and resolve it. In case of an alarm, a message consisting of an icon and text appears at the bottom of the display. Use
the left-hand navigation key to call up the information level. Use the "Diagnostics" menu to call up the error description with a help
text. The device status is divided into three groups. The message text beside this icon in the display provides information about
where to look for the error. There are the following areas: Electronic, Operation and Process.
Icon
Description
Error / Failure
Functional check
Maintenance required

9.2 8.2 Error states and alarms

— Communication Board / Electronic related error messages.
Error message LCD message
F255.004
Electronic Memory Failure
F250.003
Output ReadBack Failure
F245.002
Electronic Interface Error
—Operation related error messages.
Error message LCD message
C110.005
—Process related error messages
Error message LCD message
F240.000
C150.001
22 OI/JDF200-EN Rev. E | 2600T Series
Possible cause
Electronic NV memory corrupted
Voltage reference failure
Voltage reference failure
Possible cause
NV memory malfunctioning
Possible cause
Input current exceeding HiHi or LoLo
alarm limits
Input current exceeding LoHi or HiLo
alarm limits
Suggested action
The electronic must be replaced
Power off and on the field indicator and check if the error persists. If yes
replace the communication board as soon as possible.
Power off and on the field indicator and check if the error persists. If yes
replace the communication board as soon as possible.
Suggested action
Power off and on the field indicator and check if the error persists. If yes
replace the communication board as soon as possible.
Suggested action
Check cable connection, check connected device and/or process.
Check cable connection, check connected device and/or process.