The Meter Structure; General Specifi Cations - UNI-T UT61B Operating Manual

Hide thumbs Also See for UT61B:
Table of Contents

Advertisement

Available languages

Available languages

T
M
S
HE
ETER
TRUCTURE
See fi gure 1
1.
LCD Display
2.
Functional Buttons
3.
Blue button
4.
Rotary Switch
5.
Input terminal
G
S
ENERAL
PECIFICATIONS
1. Maximum voltage between any terminals and grounding. Refer to different range
input protection voltage.
2. 10A terminal: 10A H 250V Fast Type Ceramic Fuse 6x25mm.
3. µA mA terminal: 1 A H 250V Fast Type Ceramic Fuse 6x25mm.
4. Maximum display 4000.
5. Analogue bar graph 41 segments
6. Measurement speed: Updates 2 ~3 times/second
7. Range: auto or manual
8. Overload indication: OL
9. Operating temperature: 0°C~40°C (32°F ~104°F)
10. Relative Humidity:
11. Storing temperature: -10°C ~50°C (14°F ~122°F)
12. Electromagnetism: Under 1V/m emission: Best Total Accuracy= Specifi c Accuracy +
Measurement 5%. Over 1V/m emission do not have any specifi c index
13. Elevation: 0~2000m
14. Battery in meter: 9V 6F22 or NEDA 1604 or IEC6LR6
15. Defi ciency of Built in Battery: LCD display "
16. Product size: 180mm×87mm×47mm
17. Net Weight: About 370g (battery include)
18. Safety compliances: IEC61010 CATIII 1000V CATIV 600V overvoltage and double
insulation standard.
19. Conform: CE
9
®
0°C~30°C : below  75%,
30°C~40°C : 50%
".

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents