Download Print this page
Sonance Sonamp DSP 2-750 MKII Instruction Manual

Sonance Sonamp DSP 2-750 MKII Instruction Manual

Multi-channel power amplifier with sonarc v2
Hide thumbs Also See for Sonamp DSP 2-750 MKII:

Advertisement

Quick Links

SONAMP MULTI-CHANNEL POWER
AMPLIFIER WITH SonARC V2
I N S T R U C T I O N M A N U A L
1-L
1-R
2-L
IN
OUT
DSP 2-750 MKII
1L
2-R
IN
OUT
1R
DSP 2-750 MKII
_
_
+
+
_
+
BRIDGE
4
MIN
DSP 2-750 MKII
S/N
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
IR
IR
CONTROL
STATUS
T10AL/250VAC
IN
CAUTION
REPLACE FUSE ONLY WITH SAME
TYPE AND RATING OF FUSE
AC 100-120V ~ 60Hz
ATTENTION
AC 220-240V ~ 50Hz
REMPLACER UNIQUEMENT AVEC
LE MEME TYPE ET CALIBRE DU
VOLTAGE TRIGGER
FUSIBLE
IN
OUT
OUT
_ _
+
+
TCP/IP
DEFAULT IP
3-30 volts AC/DC
192.168.1.50

Advertisement

loading
Need help?

Need help?

Do you have a question about the Sonamp DSP 2-750 MKII and is the answer not in the manual?

Questions and answers

Summary of Contents for Sonance Sonamp DSP 2-750 MKII

  • Page 1 SONAMP MULTI-CHANNEL POWER AMPLIFIER WITH SonARC V2 I N S T R U C T I O N M A N U A L DSP 2-750 MKII DSP 2-750 MKII DSP 2-750 MKII CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR...
  • Page 2 TABLE OF CONTENTS Safety Introduction/Box Contents Front Panel/Rear Panel Connections & Volume Level Controls Protection Circuitry & LEDs/Stacking Advanced Setup Troubleshooting...
  • Page 3: Important Safety Information

    WEEE directive, require special reuse and recycling processing. For this reason Sonance has arranged with our distributors in European Union member nations to collect and recycle this this product. Please note, only this product itself falls under the WEEE directive. When disposing of packaging and other related shipping materials we encourage you to recycle these items through the normal channels.
  • Page 4: Box Contents

    Introduction Unpacking Thank you for purchasing the Sonance Sonamp DSP 2-750 MKII Save the carton and polystyrene inserts for future safe transport in years of entertainment pleasure. To get the most out of your new Before proceeding with installation, locate the serial number on the begin installation.
  • Page 5 VOLTAGE TRIGGER FUSIBLE TCP/IP DEFAULT IP BRIDGE 3-30 volts AC/DC 192.168.1.50 NOTE: L/R LINE IN/LOOP OUTPUT CARD CAN BE REPLACED WITH SONANCE DIGITAL INPUT MODULE (SKU 93099 SOLD SEPARATELY) FOR ULTIMATE PERFORMANCE ENHANCEMENT THROUGH DIRECT CONNECTION TO A DIGITAL SOURCE.
  • Page 6: Front Panel

    AC or DC. The Voltage Output supplies a 12 volt DC signal to ready to operate. When the Sonance logo is slightly dimmed, the IR Control IR control is established via the 3.5mm mono mini input jack on the the channel LEDs will also illuminate red, indicating that the power supply is in thermal protection mode.
  • Page 7: Source Connections

    The Sonamp DSP 2-750 MKII features a removable IEC power If the electrical service is subject to frequent sags, spikes or cord (see Figure 6). A 14 gauge EIA standard 120 volt grounded power cord is initially plugged in and the POWER switch is turned CAUTION: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE THE FUSE WITH ONLY THE SAME TYPE AND RATING WHEN NECESSARY.
  • Page 8: Speaker Connections

    Speaker Connections For the best sound you should use On the left side of the rear panel are the audio inputs for the left premium speaker wire that complies and right channels. In addition to the left and right inputs there are also loop outputs for each channel.
  • Page 9: Protection Circuitry And Leds

    Protection Circuitry and LEDs The DSP 2-750 MKII ships with two rack ears. Unscrew the four Phillips head screws (M4 x 0.7 pitch x 10mm long) found on each If a channel encounters a short-circuit (in bridge mode the (see Figure 15). protection circuitry will sense a short circuit across both positive speaker terminals), or extremely low impedance will cause the Side View Right...
  • Page 10 Basic Setup button. (1) Computer or tablet Connecting to Your SonARC Homepage 5. Use an IP scanner to determine the IP address of the Sonance for IOS, Advanced IP Scanner for Windows devices and LanScan for macOS.
  • Page 11 Output Settings/Output Volume General Settings Tab Output Name The Advanced Setup automatically starts out on the General Settings tab. This tab is used to set up your MKII with a network network connection, auto on method and other basic information. be powering.
  • Page 12 IP Subnet Mask Voltage The third setting in the IP SETUP section is the IP Subnet Mask. This is an advanced network setup function. Under most immediately when the trigger voltage has been removed. When a network administrator. power up sequence. This mode complies with EU energy saving standards.
  • Page 13: Input Setup

    Mono. DSP Preset NOTE: FRONT PANEL VOLUME CONTROLS OVERWRITE THIS SETTING. Apply any of the available Sonance DSP presets to each channel of Maximum Volume IP or IR can be used to limit how loud the speakers will play in certain areas.
  • Page 14 1. Import speaker preset to a location on your computer. This can Test Signal be accomplished by saving a DSP preset downloaded from Sonance website. The SonARC software includes a built in pink noise generator. 2. Select the location you would like to store the new preset using The pink noise signal can be used in conjunction with a real time the SELECT PRESET TO EDIT pull down menu.
  • Page 15: Filter Type

    Parametric EQ Crossover LP Xover / HP Xover EQ. Adjustments made to the EQ will be displayed on the output frequency response graph. We strongly suggest not adjusting the Frequency EQ without proper measurement equipment. Filter Type EQ Frequency Hz available in the pull down menu.
  • Page 16 2 (1 stereo pair) Power Output - 8 ohms (Stereo) 500 Watts RMS per channel (all channels driven) Power Output - 4 ohms (Stereo) 750 Watts RMS per channel (all channels driven) Power Output - 8 ohms (Bridged) 2000 Watts Total Harmonic Distortion 0.4% (1kHz, 8 ohms) 0.3% (1kHz, 4 ohms) Input Gain...
  • Page 17 APPENDIX A LED Indicator Explanation Dim White Power Button Power Button Blinking The amp is in ID Amp Mode (see page 9). Green LED Signal is present (>1.0mv) on channel. Blinking Green Signal is going above and below the active level or between songs. Blinking Red The channel is being over driven.
  • Page 18 Out of the Box Troubleshooting Cause: The SonARC bridging option is engaged but the speakers are No Power Front panel Power LED does not illuminate when AC cord is plugged into an outlet and the amp is switched on. Set the bridge mode to OFF. If audio output is still unavailable, contact Dana Innovations Technical Support.
  • Page 19: Factory Reset

    Reset the 1L volume control to maximum. Test playback to see if the speaker connected to the non- functioning channel works. For additional support, contact Dana Innovations Technical Support www.techsupport@sonance.com. that channel at the source or with the interconnect cable for the non-functioning channel. are functioning.
  • Page 20 Product, and does not include labor or parts caused by accident, return merchandise number (RMA), and must deliver the Product to Sonance shipping prepaid during the warranty period, together with the original sales receipt, or invoice or other satisfactory proof of purchase.