Slide 40
A resistance check across
Removing the Heating Element
Slide 41 -
Slide 42
TH1 thermostat should
indicate a closed switch
TH3
Thermostat
Safety
TH2
Thermostat
Hi-Limit
Heating
Element
TH1
Thermistor
The thermistor
resistance should be
approximately 10,000
OHMS @ 77F and
increase with a
temperature rise
Heater Assembly
viewed from above