Test The Drive Speed - Stowed Position - Genie GRC-12 Service Manual

Hide thumbs Also See for GRC-12:
Table of Contents

Advertisement

September 2016
REV B
B-9
Test the Drive Speed -
Stowed Position
Genie specifications require that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
Proper drive functions are essential to safe
machine operation. The drive function should
respond quickly and smoothly to operator control.
Drive performance should also be free of
hesitation, jerking and unusual noise over the
entire proportionally controlled speed range.
Note: Perform this procedure with the machine on
a firm, level surface that is free of obstructions.
1 Create start and finish lines by marking two
lines on the ground 40 feet / 12.2 m apart.
2 Turn the key switch to platform control and pull
out the red Emergency Stop button to the on
position at both the ground and platform
controls.
3 Lower the platform to the stowed position.
4 Choose a point on the machine; i.e., contact
patch of a tire, as a visual reference for use
when crossing the test line.
5 Check to make sure the low drive speed light is
off. If the low dive speed light is on, press the
drive speed select button to turn off the low
drive speed function.
6 Press and hold the drive/steer function enable
switch on the control handle.
Part No. 227123
Section 3 • Scheduled Maintenance Procedures
CHECKLIST B PROCEDURES
a
b
c
7 Move the control handle in the direction
indicated by the blue arrow on the control panel
until the machine begins to move forward.
8 Bring the machine to top drive speed before
reaching the start line. Begin timing when the
selected reference point on the machine
crosses the start line.
9 Continue at full speed and note the time when
your reference point on the machine passes the
finish line. Refer to Section 2, Specifications .
GRC
drive/steer function enable switch
slow drive speed button
blue arrow
3 - 17

Advertisement

Table of Contents
loading

Table of Contents