12. Taking the product out of operation

12.1 Resetting the product

Resetting the AQtap removes it from its WMS group. WMS still
tries to receive data from the AQtap and creates alarms until IMEI
no. and telephone no. are removed from the AQtap water
dispenser in WMS. The logged data are kept.
A new AQtap can be commissioned and replace the reset
AQtap in WMS.
The reset AQtap can be commissioned again in another WMS
group with the assigned smart card.
12.1.1 Entering the service menu
1. Place the ServiceCard on the right smart card reader,
2. enter PIN code,
3. press "OK" to go to the next menu item.
12.1.2 Alarms
1. Alarm sign (red) is displayed,
2. press "OK" to go to the next menu item.
12.1.3 Warnings
1. Warning sign (yellow) is displayed,
– "download" button is not displayed.
2. Press "download" button and keep it pressed for
approximately 20 sec.
– "download" button is displayed, as long as it is pressed.
3. Display flashes to confirm successful reset of the AQtap,
– AQtap is idle for a short time.
4. Enter PIN code again to continue, or remove ServiceCard.
12.2 Taking the product out of operation
1. Close the shut-off valve.
2. Disconnect the AQtap from the power supply, both grid and
solar.
3. Open the cabinet.
4. Disconnect the blue battery cable from the - pole (left side of
the battery). Place it securely so it cannot touch the battery
poles during transportation.
5. Disconnect the water inlet.
6. Unscrew the fastening screws and take the AQtap off the wall.
7. For storage and transportation see section 3.1 Transporting
the product.

12.3 Preparing the product for disposal

The waste batteries must be disposed of
Note
according to local regulations!
1. Close the shut-off valve.
2. Disconnect the AQtap from the power supply, both grid and
solar.
3. Open the cabinet,
4. Disconnect the battery at both poles.
5. Unscrew and remove the screw of the battery clamp.
6. Lift and remove the battery clamp.
7. Take out the battery.
8. Disconnect the water inlet.
9. Unscrew the fastening screws and take the AQtap off the wall.
10. Open the control unit at the back and take out the battery.
11. Dispose of both batteries according to local regulations,
12. Dispose of the AQtap, see section 14. Disposing of the
product.