7.1.1 Power supply
The AQtap can to be operated with grid and / or solar power. It
uses the power supply in the following hierarchy:
1. solar power,
2. grid power,
3. battery.
Using solar power requires a connected battery. The internal
battery is loaded when grid or solar power is available, and is
used as a backup power for approximately 12 hours of operation.
After discharging the backup battery, tapping water will not be
possible right away when power (solar radiation) is on again, until
the battery is recharged. If the internal battery is not powerful
enough, it can be substituted by an external battery.
Depending on the solar radiation and degree of
AQtap utilization the internal battery and
charging with solar power can be insufficient.
Note
In cases where tapping is not possible after using
the backup battery, an external battery with MPPT
solar charger can be used.
See section Power supply requirements.
7.1.2 Water supply
The water supply must provide clean drinking water. See section
Water supply requirements.

7.2 Applications

7.2.1 Intended use
The AQtap is intended for dispensing drinking water and
handling the smart cards for various actions. The quality of the
dispensed water must comply with the drinking water
standards of the WHO.
The aqTOP is intended for handling the smart cards for
various actions, it does not include the hydraulic part.
The AQtap / aqTOP interface is intended to be operated with
fingers and smart cards only.
The smart cards are intended for handling water credits and
accessing the AQtap functions according to the different rights
of the smart card holders.
Observe the technical data specified in section 13. Technical
data.
7.2.2 Improper use
Danger
Poisoning
Improper use can lead to personal injury!
• The AQtap dispenser must be used with water
complying with WHO drinking water standards.
• All parts and materials used in the hydraulic
system must be suitable for drinking water
appliances.
Improper use can lead to damage to the
equipment!
The AQtap dispenser must be used with water
complying with WHO drinking water standards
Caution
and the technical data.
The AQtap interface must only be operated
with smart cards and with fingers.
The operational safety of the product is only guaranteed, if it is
used in accordance with section 7.2.1 Intended use.
The AQtap must not be used for other media than drinking
water.
The AQtap interface must not be operated or treated with any
kind of tools or items.
The AQtap must not be used if it is damaged, after improper
repair or after unauthorized modification.
Other applications or the operation of the AQtap
in ambient and operating conditions, which are
not approved, are considered improper and are
Caution
not permitted. Grundfos accepts no liability for
any personal injury or damage resulting from
incorrect use.

7.3 Identification

7.3.1 Nameplate
1
2
3
4
5
6
7
8
9
10
11
Fig. 6
Nameplate
Pos.
Description
1
Type (example), see 7.3.2 Type key
2
Product number
3
Supply voltage, grid
4
Max. power consumption
5
Ambient temperature
For Q1 - Q4, see AQtap standard flow meter
6
parameters
7
Supply voltage, solar panel
8
Pressure range for water supply
9
Max. pressure for water supply
10
Production date code (yyww)
11
Serial number
12
AC power supply frequency
13
Protection class of cabinet
14
Temperature range for water supply
15
Mounting orientation
16
State of origin (assembly)
17
CE mark (if applicable)
18
Manufacturer
7.3.2 Type key
Code
Example:
Product name
AQT
AQT
Type
AA
AQtap
AO
aqTOP
Device
ST
Standard
Version
1
Version 1
12
13
14