10.3 Replacing the SIM card

Switch off the power supply, both grid and solar,
and disconnect the battery before replacing the
Caution
SIM card. The SIM card will not be read by the
AQtap until it was powered off and on again.
Disable the PIN protection of the SIM card. PIN
Caution
protected SIM cards lead to malfunction.
10.3.1 Preparing the new SIM card
1. Insert the SIM card into a mobile phone, and set the "PIN
code request" option to "OFF".
2. Write down the following:
– Mobile phone number of the SIM card.
10.3.2 Replacing the SIM card
1. Close the shut-off valve.
2. Switch off the power supply, both grid and solar.
3. Open the cabinet.
4. Disconnect the blue battery cable at the minus (-) pole on the
left side.
5. Take out the SIM card.
6. Insert the new SIM card into the CIM.
– Place the SIM card in a way that it fits in the mould of the
slide.
– Slide the SIM card into the slot.
7. Connect the blue cable to the minus (-) pole on the left side.
8. Close the cabinet and lock it with the keys.
9. Open the shut-off valve.
10. Switch on the power supply.
10.3.3 Updating the AQtap settings in WMS
1. Go to Settings > Dispensers
2. Select the AQtap.
3. Update SIM card: enter phone number with country code.
Select telco operator.
4. Save the settings.
– The updating process can take up to several hours,
depending on the GSM network status on AQtap installation
site.

11. Fault finding

If the AQtap does not operate properly:
1. Carry out maintenance, see section 10.1 Maintaining the
product.
2. Check for displayed warning or alarm codes by means of the
service menu / ServiceCard.
3. Restart the AQtap.
If the AQtap still does not operate properly, have the AQtap
serviced by a Grundfos SSP (sales and service partner).

11.1 Warning and alarm codes

11.1.1 Warnings
Code Name
External
015
communication fault
Site acceptance test
025
failed
036
Valve leakage
058
Low flow
084
Memory fault
157
Time fault
159
CIM modem fault
160
SIM card fault
Description
No data has been sent to WMS
within 48 hours
Site acceptance test (SAT) did
not succeed.
Valve is closed, but flow is
detected
Valve is open, but flow is too low
Missing or faulty SD card
Real time clock has not been
updated
CIM 270 connection lost
Missing or faulty SIM card in CIM
270
Code Name
No connection to
301
dispenser
11.1.2 Alarms
Code Name
028* Battery low
032
Overvoltage
040* Supply voltage fault
059
No flow
Internal voltage too
074
high
Internal voltage too
075
low
Internal
076
communication fault
088
Sensor fault
154
Display fault
Flow sensor supply
161
fault
Signal fault, flow
169
sensor
210
Pressure too high
211
Pressure too low
Credit download is
302
not confirmed
* code 028 indicates that the backup battery is used for some
time already and needs to be recharged. Each time the water
button is pressed to tap water, alarm code 028 is displayed
and the tapping is stopped immediately.
When solar radiation is back again, recharging of the battery
starts and code 040 is displayed. It takes approximately 15
minutes with code 040 continuously displayed, until the battery
is recharged over a certain voltage, the AQtap is restarted
automatically and is then operable again.
If this happens more often, an external battery with MPPT
solar charger can be used.

11.2 Restarting the AQtap

11.2.1 Entering the service menu
1. Place the ServiceCard on the right smart card reader.
2. Enter PIN code.
3. Press "OK" to go to the next menu item.
11.2.2 1. Alarms
1. Alarm sign (red) is displayed.
– "download" button is not displayed.
2. Press "download" button and keep it pressed for
approximately 20 sec.
– "download" button is displayed, as long as it is pressed.
3. Display flashes to confirm successful restart of the AQtap.
– AQtap is idle for a short time.
4. Enter PIN code again to continue, or remove ServiceCard.
Description
No connection to dispenser in 48
hours
Description
Battery voltage is too low
Overvoltage
Supply voltage too low or missing
valve is open, but no water is
dispensed
Internal power supply voltage is
too high
Internal power supply voltage is
too low
Internal error on the FM board
Grundfos sensor communication
error
Internal error on the HMI board
Supply voltage for Grundfos
sensor too low
Signal fault, flow sensor
Water pressure too high (> 4 bar)
Water pressure too low
(< 0.1 bar)
Credit download is not confirmed
19