5.2.4 F1 - COMMUNICATE POWER ON STATUS
This command is used to determines if the printer power was turned off in the middle of a command as
shown by status byte 6, bit 4.
5.2.4.1 Command Format
-----------------------------------------------------------------------
BYTE BIT CONTENT
0-1
1B66 - Command prefix
2
F1 - Communicate Power On Status
3
Cmd. Extension
7-0 Reserved (always = ' 0 x00' )
-----------------------------------------------------------------------
TYPE
LENGTH
hex
2
hex
1
hex
1
Command Set Reference — Page 71 of 183