Z-5R NET
www.ironlogic.me
4. SPECIFICATIONS
- Maximum supported Keys number: ................................................................................2024;
including:
- Normal Keys for passing the door,
- Master Keys for programming,
- Blocking Keys for Blocking Mode (can double as Normal Keys).
- Lock type choice jumper ...........................................................................................Present;
- Lock opening time range: ....................................0.1...25.5 sec. (factory pre-set to 3.0 sec.);
- Power supply voltage: ...............................................................................................12 V DC;
- Standby current: ...........................................................................................................30 mA;
- Protection from incorrect connection: .........................................................................Present;
- Indication of operation and programming modes: .......................................Audial and visual;
- External interface: ......................................................................................................RS-485;
- Link distance to remote controller via RS-485: ..................................................max 1,200 m;
- Power output:..........................................................................Field effect transistor, up to 5A;
- Case material: ......................................................................................................ABS plastic;
- PCB dimensions, mm: ........................................................................................60 x 50 x 12;
- Weight: ............................................................................................................................80 g.
Z-5R NET Networked operation specifications.
- Maximum cards/keys number: 2024;
- Event log memory: 2048;
- Maximum Controllers on the network: 255;
- RS-485 baud rate: 19,200/57,600 bps (negotiated automatically).
If a door sensor is present, additional events "Door broken in" and "Door not closed" become
available. To avoid real-time clock failure in case of power failure, install a 3V CR2032 lithium cell
battery into the battery socket (as per Figure 3).
Controller network logical address is initially set to 1.
Additional operation modes:
- Blocking mode access granted only to Blocking keys, but to Normal keys access is denied.
- Accept mode all keys used are granted access and also are stored into key database.
These modes are activated by a Master Key.
5. OPERATING CONDITIONS
Ambient temperature: .........5...40°C.
Humidity: .............up to 80% at 25°C.
Controller specifications may differ from described here, when operating under non-
recommended conditions.
The controller should be operating in absence of: atmospheric precipitation, direct sunlight,
sand, dust, and moisture condensation.