11.2

Door Settings

Relay Output Delay Time
To set door relay strike time
Door Open Detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in
magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside
buzzer will beep automatically to remind people to close the door and continue for 1 minute before
switching off automatically.
Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact
of the lock, if the door is forced open, or if the door is opened after 20 seconds of the
electro-mechanical lock not closed properly, the inside buzzer and alarm output will both operate. The
Alarm Output time is adjustable between 0-3 minutes with the default being 1 minute.
To disable door open detection. (Factory
default)
To enable door open detection
Alarm output time
To set the alarm output time (0-3 minutes)
Factory default is 1 minute
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers
in a 10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10
minutes, depending on the option selected below.
Normal status: No keypad lockout or
alarm (factory default)
Keypad Lockout
Alarm Output
To remove the alarm
To reset the Door Forced Open warning
To reset the Door Open Too Long warning
4
0~99
# *
0-99 is to set the door relay time 0-99 seconds
6
0
#
6
1
#
9
0~3
#
7
0
# (Factory default setting)
7
1
#
7
2
#
Read valid card or Master Code #
Close the door or Read valid card or Master Code #
9