NO and COM: Fail-secure lock, when power on, the lock is opened.
NC and COM: Fail-safe lock, when power off, the lock is opened.
8.
To Reset to Factory Default
To reset to factory default, power off the device, remove the keypad from the back cover, press
the RESET key(K2) on the PCB, hold it and power on, keeping pressing it until hear three
beeps, means reset to factory default successfully.
Note: Reset to factory default, the user's information is still retained.
9. Anti Tamper Alarm
The BC-2010 is built-in tamper switch. If the keypad is removed from the cover then the
tamper alarm will operate.
10.
Sound and Light indication
Operation Status
Power on
Stand by
Press keypad
Operation successful
Operation failed
Enter into programming mode
In the programming mode
Exit from the programming
mode
Open the door
Alarm
11.
BC-2010 Detailed Programming Guide
11.1
User Settings
To enter the programming mode
To exit from the programming mode
Note that to undertake the following programming the master user must be logged in
Red Light
Green Light
-
Bright
Bright
-
-
-
-
Bright
-
-
Bright
-
-
-
Bright
-
-
Bright
Bright
-
*
Master code #
888888 is the default factory master code
*
(Before exit from the programming mode, press # is to
confirm the operation step.)
6
Yellow Light
Buzzer
-
Short Ring
-
-
Short Ring
-
Short Ring
-
3 Short Rings
-
Short Ring
Bright
-
Short Ring
-
Short Ring
-
Alarm
-
-