Electric Characteristics
10. Electric Characteristics
FTXZ25NVMM
FTXZ35NVMM
FTXZ50NVMM
Symbols:
MCA
MFA
Notes:
1. Maximum allowable voltage variation between phases is 2%.
2. Select wire size based on the larger value of MCA.
3. Instead of fuse, use circuit breaker.
4. Be sure to install an earth leak detector.
16
Indoor Unit
Outdoor Unit
RXZ25NVM
RXZ35NVM
RXZ50NVM
: Min. circuit amps (A)
: Max. fuse amps (A)
(This unit uses an inverter, which means that an earth leak
detector capable of handling high harmonics must be used in
order to prevent malfunctioning of the earth leak detector.)
Power Supply
Hz - Volts
Voltage Range
50 - 220
MAX. 50 Hz, 264 V
50 - 230
MIN. 50 Hz, 198 V
50 - 240
60 - 220
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
60 - 230
50 - 220
MAX. 50 Hz, 264 V
50 - 230
MIN. 50 Hz, 198 V
50 - 240
60 - 220
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
60 - 230
50 - 220
MAX. 50 Hz, 264 V
50 - 230
MIN. 50 Hz, 198 V
50 - 240
60 - 220
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
60 - 230
Split Type Air Conditioners FTXZ-N Series
EDMY041425
MCA
MFA
10.5
16
13.25
16
15
16
3D087024