An Example For Defining The Eop For Ab1B-3U Driver In Vacuum; Environment - Nanomotion AB1B-3U Driver User Manual

Driver
Table of Contents

Advertisement

AB1B-3U Driver User Manual
Technical Data
4.3.1
An Example for Defining the EOP for AB1B-3U
Driver in Vacuum Environment
An example for using the graph and table (Figure 4 and
Table 5) for the AB1B-3U driver and HR8 motor:
A vacuum application requires 10N at a velocity of 100mm/sec. The
graph shows that this point of operation corresponds to the curve "d".
The table shows that curve "d" and a vacuum environment require that
a duty cycle of 17% will not be exceeded and the maximum
continuous operation time is limited to 72 seconds.