Technical Information
Procedures for Flat End and
Conical End Models
(continued)
KPP PPU

Procedure C

Non-directional and Directional KPP conical end models. Models included: KPPG2XXXX.
Installation steps:
1. Turn in (CW) by hand until bottom end gently touches the speed ring.
2. Back out (CCW) 2 turns. Continue backing out until the KPP orientation notch is 180±15° to
motor shaft center line, (reference
Motors
Only, page 17).
3. Using the 1/2 inch wrench to hold the KPP, torque the lock nut to 13 N•m [10 lbf•ft] with an
11/16 inch hex wrench.
Special KPP CONE END models include: KPPG29XXX. Installation range is application specific:
1. Turn in (CW) by hand until bottom end gently touches the speed ring.
2. Back out (CCW) 1 turn. Continue backing out until the KPP Orientation Notch is 180° to motor
shaft center line, acceptable range is determined per application, (reference
End Models, Series 51 and 51-1 Cartridge Motors
3. Using the 1/2 inch wrench to hold the KPP, torque the lock nut to 13 N·m [10 lbf·ft] with an 11/16
inch hex wrench.

Procedure D

When Directional KPP flat end models are used for sensing speed only, the same installation steps
in Procedure A are acceptable. Models included: KPPG13XXX, KPPG14XXX, KPPG15XXX,
KPPG18XXX.

Procedure E

Fixed position. Non-directional and Directional KPP conical end models KPP3XXXX and flat end
models KPP4XXXX. Installation steps:
1. Insert PPU housing; align the hole in mounting flange with mounting hole in block housing.
2. Torque M6x12 capscrew 8 ± 1 N•m [5.9 ± 0.7 lbf•ft].
11029257 • Rev BB • July 2013
Directional Conical End Models, Series 51 and 51-1 Cartridge
Only, page 17).
Directional Conical