Liquid level sensor, upgrade kit, upgrade to support batteryless floats
Hide thumbs Also See for LevelMaster 7100:
Table of Contents

Advertisement

Figure 17: Connections of mixed board types: new board as intermediate sensor
Figure 18: Connection of mixed board types: new board as last sensor
3.
Verify that the communication LEDs (D18 and D19) lit up intermittently as the
unit receives and transmits signals on the communication port. If these LEDs do
not lit up, check the wiring.
4.10 Verify installation using PCCU
If the LevelMaster is connected to an ABB Totalflow flow computer or remote
controller, verify that the LevelMaster communication interface is able to detect the
unit and that the correct measurements are being displayed.
To verify from PCCU:
1.
Start PCCU.
2.
Connect to the flow computer or remote controller.
3.
On the tree view, click on LevelMaster.