Versastudio Settings - Ametek PMC BOOSTER Series Hardware Manual

Table of Contents

Advertisement

VERSASTUDIO SETTINGS

Starting with VersaStudio 2.43.3; there is a BOOSTER.INI file that allows users to select parameters for
different models of boosters. This file lives at C:\My Data\VersaStudio\Settings\Boosters.ini
A published Technical Note gives complete details on this process.
Here is an example for the PMC BOOSTER10A
<Booster2>
Name=PMC BOOSTER10A
Ein=1
Eout=1
Iin=1000
Iout=1000
FixedRange=0.2
MaxPosCurrent=10
MaxNegCurrent=10
MaxPosVolts=6
MaxNegVolts=1
BoosterType=PMC
</Booster2>
This is selected ON/OFF in the software through Tools  Options  Instrument  Booster drop-down
box.