164
Basic device
Basic device
without Ex protection
with EEx-d protection
(flameproof casing)
Layers 1 and +2 according to PROFIBUS PA, transmission technique according to IEC 1158-2;
slave function; layer 7 (protocol layer) according to PROFIBUS DP,
EN 50170 standard with the extended PROFIBUS functions
(all data acyclic, manipulated variable, feedbacks and status also cyclic)
Four connections to master class 2 are supported,
automatic connection setup 60 s after break in communication;
PROFIBUS PA profile B, version 3.0, more than 150 objects
SIMATIC PDM; supports all device objects. The software is not included in the scope of delivery
Screw terminals 2.5
Screw terminals 2.5
AWG28-12
AWG28-12
Cable gland M20 x 1.5 or
EEx d certified cable
½-14 NPT
gland M20 x 1.5,
½-14 NPT or M25 x 1.5
Female thread G¼
Female thread G¼
DIN 45141 (¼-18 NPT)
DIN 45141 (¼-18 NPT)
Basic device
with EEx ia/ib protection
Typical 10 ms
126 (when delivered)
Screw terminals 2.5
AWG28-12
Cable gland M20 x 1.5 or
½-14 NPT
Female thread G¼
DIN 45141 (¼-18 NPT)
< 5 V
<75 mA
<160 mA
<120 mW
< 1 µF
< 1 mH
SIPART PS2 PA Manual
Basic device
with EEx n protection
Screw terminals 2.5
AWG28-12
Cable gland M20 x 1.5 or
½-14 NPT
Female thread G¼
DIN 45141 (¼-18 NPT)
< 5 V
<75 mA
<160 mA
<120 mW
< 1 µF
< 1 mH
A5E00127926--05