Siemens SIPART PS2 Operating Instructions Manual

Siemens SIPART PS2 Operating Instructions Manual

Electropneumatic positioner with mechanical limit switch module
Hide thumbs Also See for SIPART PS2:

Advertisement

SIPART
Electropneumatic positioner
SIPART PS2 with mechanical limit
switch module
Operating Instructions (Compact)
Supplement to the equipment manuals
6DR5**0-*N*3*-**** in the plastic enclosure
6DR5**1-*N*3*-**** in the aluminum enclosure
6DR5**2-*N*3*-**** in the stainless steel enclosure
6DR5**0-*E*3*-**** in the plastic enclosure
6DR5**1-*E*3*-**** in the aluminum enclosure
6DR5**2-*E*3*-**** in the stainless steel enclosure
04/2007
A5E01179056-01
Introduction and general
safety notes
Description
Installing
Connecting
Scope of delivery
Certificates
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIPART PS2

  • Page 1 Introduction and general safety notes Description Installing SIPART Connecting Electropneumatic positioner SIPART PS2 with mechanical limit Scope of delivery switch module Certificates Operating Instructions (Compact) Supplement to the equipment manuals 6DR5**0-*N*3*-**** in the plastic enclosure 6DR5**1-*N*3*-**** in the aluminum enclosure...
  • Page 2 Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
  • Page 3: Table Of Contents

    Mechanical limit switch module wiring diagram, not Ex...............17 Mechanical limit switch module wiring diagram, EEx i..............18 Connecting the mechanical limit switch module ................19 Scope of delivery ............................. 21 Certificates............................... 23 SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 5: Introduction And General Safety Notes

    For example, in Germany these are: ● Operational safety regulations ● Directive for the installation of electrical systems in hazardous areas DIN EN 60079-14 (previously VDE 0165, T1) SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 6: Qualified Personnel

    Isolate the device from power using a circuit breaker. Protect the device from shocks (otherwise the degree of protection IP66 is not guaranteed). Protective insulation; device in protection class II SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 7: Description

    ● Subsequent installation of the mechanical limit switch module of both the non-intrinsically safe and the intrinsically safe version. For more information on the electropneumatic positioner, please see its Programming Manual. SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 9: Installing

    Before you install option modules, you must open the housing of the positioner. Please note that the degree of protection IP66/NEMA 4x is not guaranteed when the housing is open. SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 10: Set Of Signs For The Non-Intrinsically Safe Version

    2. To do this, loosen the four fixing screws of the housing cover with a Phillips screwdriver. 3. Disconnect the power supply cables or isolate them from power. 4. Remove the module cover. 5. To do this, remove the two screws with a screwdriver. SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 11 ⑧ Actuating disc for A2, terminals 51 and 52 ⑲ Warning label on the side across from the type plate ⑪ module ⑳ Wiring diagram ⑫ Alarm unit SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 12 ● A binary output for the output of a group fault message. ● Two switches for signaling two limits that can be set mechanically. These two switches are electrically independent from the rest of the electronic system. SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 13 13. From the set of plates enclosed, select the plates that are already on the standard version of the module cover. Stick the selected plates to the installed module cover as on the standard version. 14. Reestablish all electrical connections. SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 14: Setting The Limits Of The Mechanical Limit Switch Module

    To do this, open and close the actuator several times while at the same time holding the actuating discs steady. SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 15: Connecting

    This required protection applies to the operation of the module with the following voltages: • > AC 16 V • > DC 35 V, low voltage SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 16 1. Insulate the cables in such a way that the insulation is flush with the terminal when plugging in the wires. 2. Fit ferrules to the ends of stranded wires. SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 17: Mechanical Limit Switch Module Wiring Diagram, Not Ex

    Connecting 4.2 Mechanical limit switch module wiring diagram, not Ex Mechanical limit switch module wiring diagram, not Ex Figure 4-1 Mechanical limit switch module 6DR4004-8K SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 18: Mechanical Limit Switch Module Wiring Diagram, Eex I

    Electrical circuits Only certified intrinsically safe electrical circuits can be connected as power supply, control, and signal electrical circuits. Figure 4-2 Mechanical limit switch module 6DR4004-6K, EEx i SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 19: Connecting The Mechanical Limit Switch Module

    5. Tighten the screw ⑱ on the transparent cover ⑲. 6. Attach the wires of each switch in pairs on the lug of the circuit board. Use the cable ties ⑳ included with the delivery for this. SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 20 Connecting 4.4 Connecting the mechanical limit switch module Figure 4-3 Connecting the cables ⑱ Screw ⑲ Cover ⑳ Cable tie SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 21: Scope Of Delivery

    ● One mechanical limit switch module with accessories ● These Operating Instructions (Compact) "SIPART PS2 with mechanical limit switch module" to be found on the CD included with delivery ● One housing cover with enlarged aperture ●...
  • Page 23: Certificates

    Certificates Declaration of conformity for low-voltage version SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 24 Certificates SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 25 Certificates Declaration of conformity for Ex version SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 26 Certificates SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 27 Certificates Certificate SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...
  • Page 28 Certificates SIPART PS2 with mechanical limit switch module Operating Instructions (Compact), 04/2007, A5E01179056-01...

Table of Contents