  • Page 1 USER MANUAL MODEL: TP-900UHD HDMI/HDBaseT Receiver/Switcher/Scaler KRAMER.RU...
  • Page 2 TP-900UHD HDMI/HDBaseT Receiver/Switcher/Scaler 4 Rubber feet 1 Power supply (12V DC) 1 Quick Start Guide Step 2: Get to know your TP-900UHD Feature Function IN LED Lights green when the HDMI input is selected and blue when HDBT is selected. It flashes if no...
  • Page 3 Always use Kramer high-performance cables connecting AV equipment to the TP-900UHD. Step 5: Connect the power If the unit does not receive power via PoE, connect the 12V DC power adapter to the TP-900UHD and plug the adapter into the main electricity.
  • Page 4: Table Of Contents

    Connecting the Ethernet Port via a Network Hub or Switch RS-232 Control over HDBaseT IR Control Over HDBaseT OPERATING THE TP-900UHD Operating the TP-900UHD Using the Front Panel Buttons Using the OSD The OSD Menu Structure Operating the TP-900UHD Remotely...
  • Page 5 Common Commands Device Specifi c Commands FIGURES Figure 1: TP-900UHD HDMI HDBaseT Receiver Switcher Scaler Front Panel Figure 2: TP-900UHD HDMI HDBaseT Receiver Switcher Scaler Rear Panel Figure 3: Connecting the TP-900UHD HDMI/HDBaseT Receiver/Switcher/Scaler Figure 4: Local Area Connection Properties Window...
  • Page 6: Introduction

    INTRODUCTION INTRODUCTION Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and aff ordable solutions to the vast range of problems that confront video, audio, presentation, and broadcasting professionals on a daily basis. In recent years, we have redesigned and upgraded most...
  • Page 7: Getting Started

    2.1 Achieving the Best Performance To achieve the best performance: • Use only good quality connection cables (we recommend Kramer high-performance, high-resolu- tion cables) to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables) •...
  • Page 8: Safety Instructions

    Advanced Recycling Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility. For details of Kramer’s recycling arrangements in your particular country go to our recycling pages at http://www.kramerav.
  • Page 9: Overview

    OVERVIEW OVERVIEW The TP-900UHD comprises HDBaseT signal receiver and additional local HDMI input and can perform CLEAN SWITCH between these two inputs. It is capable to scale the picture to match the resolution of the monitor and can maintain stable, without intermission output HDMI signal while input signal changes format or resolution.
  • Page 10: Defining The Tp-900Uhd

    DEFINING THE TP-900UHD DEFINING THE TP-900UHD Figure 1 defines the front panel of the TP-900UHD. Figure 1: TP-900UHD HDMI/HDBaseT Receiver/Switcher/Scaler Front Panel № Feature Function IN LED Lights green when the HDMI input is selected and blue when HDBT input is select- ed.
  • Page 11: Figure 2: Tp-900Uhd Hdmi Hdbaset Receiver Switcher Scaler Rear Panel

    DEFINING THE TP-900UHD Figure 2 defines the rear panel of the TP-900UHD. Figure 2: TP-900UHD HDMI/HDBaseT Receiver/Switcher/Scaler Rear Panel № Feature Function IN LED Lights green when the HDMI input is selected and blue when HDBT input is select- ed. It fl ashes if input signal is lost...
  • Page 12: Connecting The Tp-900Uhd

    CONNECTING THE TP-900UHD CONNECTING THE TP-900UHD Figure 3: Connecting the TP-900UHD HDMI/HDBaseT Receiver/Switcher/Scaler KRAMER ELECTRONICS, LTD.
  • Page 13: Connecting The Ethernet Port Directly To A Pc

    5.1 Connecting the Ethernet Port Directly to a PC You can connect the Ethernet port of the TP-900UHD directly to the Ethernet port on your PC using a cable (straight and cross are allowed) with RJ 45 connectors. This type of connection is recommended for identifying the TP-900UHD with the factory configured default IP address.
  • Page 14: Figure 4: Local Area Connection Properties Window

    CONNECTING THE TP-900UHD Figure 4: Local Area Connection Properties Window 4. Click on Internet Protocol Version 4 (TCP/IPv4) to highlight the selection. 5. Click Properties. The Internet Protocol Properties window relevant to your IT system appears as shown in Figure 5.
  • Page 15: Remote Control Of Unit Via Hdbaset Ethernet Link

    You can connect the Ethernet port of the remote HDBaseT transmitter (if available) to the Ethernet port of a PC to obtain remote control of TP-900UHD via HDBaseT Link. All IP address configurations for PC must be the same as in previous 5.1 item.
  • Page 16: Connecting The Ethernet Port Via A Network Hub Or Switch

    5.3 Connecting the Ethernet Port via a Network Hub or Switch You can connect the Ethernet port of the TP-900UHD to the Ethernet port on a network hub using a straight through cable with RJ-45 connectors. 5.4 RS-232 Control over HDBaseT You can connect to the transmitter/receiver system via an RS-232 connection.
  • Page 17: Operating The Tp-900Uhd

    OPERATING THE TP-900UHD OPERATING THE TP-900UHD 6.1 Operating the TP-900UHD Using the Front Panel Buttons During normal operation (without the OSD), the front panel buttons performs following functions: • Pressing HDBT/HDMI alternatively select either HDBT or HDMI inputs • Pressing MENU opens the on-screen display (OSD) (an item of main menu, for example “SETUP CON- FIGURATION”), the next press closes the OSD...
  • Page 18: The Osd Menu Structure

    OPERATING THE TP-900UHD 3. Press ENTER and then using buttons + or - navigate to parameter CONTRAST. 4. Press ENTER. The contrast value parameter changes to red. 5. Press the + button to increase the value (increase the contrast) or the – button to decrease the value (decrease the contrast).
  • Page 19 OPERATING THE TP-900UHD Submenu Parameter Values Notes OUTPUT OUTPUT STANDARD 480i/60 Set Standard of output Signal CONFIGURATION 576i/50 480p/60 576p/50 720p/50 720p/59.94 720p/60 640x480/60 640x480/72 640x480/75 640x480/85 800x600/60 800x600/72 800x600/75 800x600/85 1024x768/60 1024x768/70 1024x768/75 1024x768/85 1152x864/75 1280x768/60 RB 1280x768/60 1280x768/75...
  • Page 20 OPERATING THE TP-900UHD Submenu Parameter Values Notes OUTPUT 3840x2160p25 CONFIGURATION 3840x2160p30 OUTPUT STANDARD 3840x2160p50 3840x2160p60 NO TEST SIGNAL - default Select any TEST Signal for output COLOR BARS100% instead of HDMI or HDBT input. SPLIT BARS 100% TILT LINE TEST SIGNAL...
  • Page 21: Operating The Tp-900Uhd Remotely

    You can control the TP-900UHD remotely via: • RS-232 serial commands transmitted by a serial controller. • A PC connected to the Ethernet port on the TP-900UHD via a LAN using P3000 commands (see Section 10). • A PC connected to the Ethernet port on the remote HDBT transmitter using the same P3000...
  • Page 22: The Settings That Are Recommended To Optimize Clean Switch Feature

    OPERATING THE TP-900UHD 6.5 The settings that are recommended to optimize CLEAN SWITCH feature A problem arises when for OUTPUT HDCP MODE (submenu OUTPUT CONFIGURATION) is selected the option FOLLOW INPUT, and when simultaneously one of switchable input signal contains HDCP encryption, but another don’t contain.
  • Page 23: Upgrading The Firmware

    UPGRADING THE FIRMWARE UPGRADING THE FIRMWARE The firmware can be uploaded by using the K-Upload Software. The instructions for using the K-Upload Software can be found in the “Upgrading the Firmware Using the K-Upload Software” document available for download from http://www.kramerav.com.
  • Page 24: Technical Specifications

    –40°C to +70°C (–40° to 158°F) HUMIDITY: 10% to 90%, RHL non-condensing DIMENSIONS: 18.75cm x 14.5cm x 2.54cm (W, D, H) WEIGHT: 0.75kg approx. INCLUDED ACCESSORIES: Power supply Specifications are subject to change without notice at http://www.kramerav.com KRAMER ELECTRONICS, LTD.
  • Page 25: Default Communication Parameters

    DEFAULT COMMUNICATION PARAMETERS RS-232 Baud Rate: 115,200 Data Bits: Stop Bits: Parity: None Command Format: ASCII Protocol example: #VERSION?<CR> Ethernet Name: KRAMER_ Model: TP-900UHD IP Address: 192.168.1.39 Network Mask: 255.255.0.0 Gateway: 0.0.0.0 TCP Port #: 5000 UDP Port #: 50000...
  • Page 26: Kramer Protocol 3000

    KRAMER PROTOCOL 3000 10 KRAMER PROTOCOL 3000 The TP-900UHD can be operated using serial commands from a PC, remote controller or touch screen using the Kramer Protocol 3000. This section describes: • Kramer Protocol 3000 syntax (see Section 12.1) • Kramer Protocol 3000 commands (see Section 12.2) 10.1...
  • Page 27: Device Long Response

    KRAMER PROTOCOL 3000 Device Long Response Echoing command: Start Address (optional) Body Delimiter device_id@ Command SP [Param1 ,Param2 …] result CR = Carriage return (ASCII 13 = 0x0D) LF = Line feed (ASCII 10 = 0x0A) SP = Space (ASCII 32 = 0x20)
  • Page 28: Entering Commands

    Entering Commands You can directly enter all commands using a terminal with ASCII communications software, such as HyperTerminal, Hercules, etc. Connect the terminal to the serial or Ethernet port on the Kramer device. To enter CR press the Enter key.
  • Page 29: Kramer Protocol 3000 Commands

    KRAMER PROTOCOL 3000 10.2 Kramer Protocol 3000 Commands Common Commands Command Description Protocol handshaking BUILD-DATE? Read device build date ETH-PORT Change protocol Ethernet port ETH-PORT? Query protocol Ethernet port FACTORY Reset to factory default confi guration HELP List of commands...
  • Page 30 Get Command syntax Y Control_Type=1, Function For example: Y 1,200 Device response: ~id=01Y Control_Type=1, Function, Param For example: ~01@Y 1,200,3 The following table lists the TP-900UHD “Y commands”. Description Function # Value Notes Input Switch Mode forced by Input Source parameter (see next item –...
  • Page 31 KRAMER PROTOCOL 3000 Description Function # Value Notes 1080sf/25 1080sf/29 1080sf/30 640x480/60 640x480/72 640x480/75 640x480/85 800x600/60 800x600/72 800x600/75 800x600/85 1024x768/60 1024x768/70 1024x768/75 1024x768/85 1152x864/75 1280x768/60 reduced blanking 1280x768/60 1280x768/75 1280x800/60 1280x960/60 1280x960/85 Output Video Resolution 1280x1024/60 1280x1024/75 1360x768/60 1366x768/60 1400x1050/60 reduced blanking...
  • Page 32 KRAMER PROTOCOL 3000 Description Function # Value Notes NO TEST SIGNAL - default COLOR BARS100% SPLIT BARS 100% TILT LINE TEST SIGNAL CROSS HATCH SPLIT CROSS HATCH MODULATED RAMPS MOVING TILT LINE AUTO 1 – HDMI priority AUTO 2 – DVI priority...
  • Page 33 KRAMER PROTOCOL 3000 Description Function # Value Notes 1080sf/24 1080sf/25 1080sf/29 1080sf/30 640x480/60 640x480/72 640x480/75 640x480/85 800x600/60 800x600/72 800x600/75 800x600/85 1024x768/60 1024x768/70 1024x768/75 1024x768/85 1152x864/75 1280x768/60 reduced blanking 1280x768/60 1280x768/75 1280x800/60 1280x960/60 Input Resolution (READ ONLY) 1280x960/85 1280x1024/60 1280x1024/75 1360x768/60...
  • Page 34 KRAMER PROTOCOL 3000 Description Function # Value Notes 3840x2160p/60 Input Resolution UNIDENTIFIED INPUT SIGNAL (READ ONLY) NO INPUT SIGNAL Image brightness [-50:50] If parameter = 0 then default brightness (100%) Image contrast [-50:50] If parameter = 0 then default contrast (100%) If parameter = 0 then default color(100%).