Hatco FLAV-R-SAVOR FSHC-5W Series Installation And Operating Manual

Hatco FLAV-R-SAVOR FSHC-5W Series Installation And Operating Manual

Portable holding cabinet culver's
Hide thumbs Also See for FLAV-R-SAVOR FSHC-5W Series:

Advertisement

hatcocorp.com
Register Online!
(see page 2)
Portable Holding Cabinet
Culver's FSHC-5W Series
Installation and Operating Manual
WARNING
Do not operate this equipment unless you
have read and understood the contents of
this manual! Failure to follow the
instructions contained in this manual may
result in serious injury or death. This
manual
contains
important
information concerning the maintenance,
use, and operation of this product. If
you're unable to understand the contents
of this manual, please bring it to the
attention of your supervisor. Keep this
manual in a safe location for future
reference.
FLAV-R-SAVOR
P/N 07.04.627.00
ADVERTENCIA
No opere este equipo al menos que haya
leído y comprendido el contenido de este
manual! Cualquier falla en el seguimiento
de las instrucciones contenidas en este
manual puede resultar en un serio lesión
safety
o
muerte.
Este
importante información sobre seguridad
concerniente al mantenimiento, uso y
operación de este producto. Si usted no
puede entender el contenido de este
manual
por
favor
supervisor. Almacenar este manual en
una localización segura para la referencia
futura.
®
Ne pas utiliser cet équipement sans avoir
lu et compris le contenu de ce manuel !
Le
contenues dans ce manuel peut entraîner
de graves blessures ou la mort. Ce
manual
contiene
manuel
importantes
l'utilisation et le fonctionnement de ce
produit. Si vous ne comprenez pas le
contenu de ce manuel, veuillez le signaler
pregunte
a
su
à votre supérieur. Conservez ce manuel
dans un endroit sûr pour pouvoir vous y
référer plus tard.
AVERTISSEMENT
non-respect
des
instructions
contient
des
informations
concernant
l'entretien,
© 2015 Hatco Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Hatco FLAV-R-SAVOR FSHC-5W Series

  • Page 1 à votre supérieur. Conservez ce manuel manual in a safe location for future supervisor. Almacenar este manual en dans un endroit sûr pour pouvoir vous y reference. référer plus tard. una localización segura para la referencia futura. © 2015 Hatco Corporation...
  • Page 2: Table Of Contents

    Central Standard Time (CST) purchase date of the unit in the spaces below (specification label located on the back of the unit). Please have this (Summer Hours: June to September— information available when calling Hatco for service assistance. 7:00 to 5:00 CST monday–Thursday...
  • Page 3: Important Safety Information

    • Turn OFF power switch, unplug power cord, and allow This unit has no “user-serviceable” parts. If service is unit to cool before performing any cleaning, required on this unit, contact an Authorized Hatco Service adjustments, or maintenance. Agent or contact the Hatco Service Department at •...
  • Page 4: Model Description

    MODEL DESCRIPTION The Flav-R-Savor Portable Holding Cabinet is constructed of ® sturdy stainless steel. It features electronically-controlled heat, POWER ON/OFF (I/O) low velocity convected air, a humidity system, and a heavy-duty, Switch insulated, glass access door. The access door can be hinged left or right, depending on the application.
  • Page 5: Specifications

    If the plug and receptacle do not Plug Configuration match, contact a qualified electrician to determine and NOTE: Receptacle not supplied by Hatco. install the proper voltage and size electrical receptacle. NOTE: The specification label is located on the back of the unit.
  • Page 6: Installation

    INSTALLATION General 4. Install the 4″ (102 mm) casters onto the bottom of the cabinet. The Flav-R-Savor Portable Holding Cabinet is shipped with most components installed and ready for operation. The NOTICE following installation instructions must be performed before Do not lay unit on side with control panel or damage to unit plugging in and operating the cabinet.
  • Page 7: Adjusting The Top Shelf

    INSTALLATION 7. Place the unit in the desired location. • Locate the unit in an area where the ambient air temperature is constant and a minimum of 70°F (21°C). Strike Plate avoid areas that may be subject to active air movements Screw or currents (i.e., near exhaust fans/hoods and air Hinge Screw...
  • Page 8: Operation

    OPERATION General 5. Set the humidity to level 1. Refer to the “Setting the Humidity Level” procedure in this section for more Use the following procedures to operate a Flav-R-Savor ® information. Portable Holding Cabinet. WARNING Read all safety messages in the IMPORTANT SAFETy INFORMATION section before operating this equipment.
  • Page 9: Setting The Air Temperature

    OPERATION Setting the Air Temperature Setting the Humidity Level Use the following procedure to set or change the air Use the following procedure to set the humidity level on temperature. humidified units. 1. Press the key to enter temperature mode (“tSP” will 1.
  • Page 10: Maintenance

    • This unit must be serviced by qualified personnel only. Service by unqualified personnel may lead to electric shock or burn. This unit has no “user-serviceable” parts. If service is required on this unit, contact an Authorized Hatco Service Drain Hose Agent or contact the Hatco Service Department at 800-558-0607 or 414-671-6350;...
  • Page 11: Removing Lime And Mineral Deposits

    MAINTENANCE Removing Lime and Mineral Deposits Use the following procedure for periodic cleaning and deliming of the water reservoir on humidified models. NOTICE Use of distilled water in water reservoir of humidified units is recommended. If non-distilled water is used, reservoir will require periodic cleaning and deliming.
  • Page 12: Troubleshooting Guide

    Blower motor defective. Contact authorized Service agent or Hatco for air inside cabinet. assistance. Incorrect voltage supplied to blower motor. Contact authorized Service agent or Hatco for assistance. Unit is leaking. The hose valve is not tight enough. Tighten drain hose by squeezing the hose valve.
  • Page 13: Limited Warranty

    Product’s purchase date by registering the Product bulbs, fluorescent lights, heat lamp bulbs, coated halogen light with Hatco or by other means satisfactory to Hatco in its sole bulbs, halogen heat lamp bulbs, xenon light bulbs, LED light discretion.
  • Page 14: Replacement Parts List

    REPLACEMENT PARTS LIST Hatco Flav-R-Savor Portable Holding Cabinet ® FSHC-5W Series Specification Label on underside of top shelf. Form No. FSHC5Wm-0415...
  • Page 15 Use of replacement parts other than those supplied by 24 Hour 7 Day Parts and Service Hatco Corporation may result in damage to the unit or Assistance available in the United States injury to personnel and will void all warranties.
  • Page 16 Lexington 803-996-9900 TENNESSEE marren Group Camp Electric Northants +44(0)1933 665313 memphis 901-527-7543 HATCO CORPORATION Register your unit online! P.O. Box 340500 Milwaukee, WI 53234-0500 U.S.A. See ImPORTaNT OWNER INFORmaTION 800-558-0607 414-671-6350 section for details. Parts and Service Fax 800-690-2966 International Fax 414-671-3976 partsandservice@hatcocorp.com...

This manual is also suitable for:

Flav-r-savor fshc-5w1-ee

Table of Contents