Test Power Supply Resistance; Test Gun Barrel Resistance - Graco Pro Xp H60T10 Instructions Manual

Electrostatic air-assisted spray gun
Table of Contents

Advertisement

Test Power
Power Supply
Supply Resistance
Test
Test
Power
Supply
1. Remove the power supply (11). See
Supply Removal and Replacement, page
2. Remove the alternator (15)
from the power supply. See
Alternator Removal and Replacement, page
3. Measure resistance from the power supply's
ground strips (EE) to the spring (11a). The
resistance should be:
• 86–110 megohms for 60 kV guns
• 130–160 megohms for 85 kV guns
4. If outside this range, replace the
power supply. If in range, go to
Test Gun Barrel Resistance, page
5. If you still have problems, refer to
Electrical Troubleshooting
Troubleshooting, , , page
Electrical
Electrical
Troubleshooting
other possible causes of poor performance, or
contact your Graco distributor.
6. Be sure the spring (11a) is in place before
reinstalling the power supply.