6. GENERATOR USE

WARNING
• Be sure to ground the generator when the
connected electrical appliance is grounded.
• Do not connect to the building's electrical
system, in order to avoid the electric shocks
and fires.
WARNING
• For continuous operation, do not exceed the
rated out-put power of generator.
• Do not make parallel connection with other
generators.
• Do not connect an extension to the exhaust pipe.
• When an extension cable is required, be sure to
use a tough rubber sheathed flexible cable
(according to IEC245 or equivalent standards).
The maxmin length of the
extension cable: 60m for cable of 1.5mm ;
100m for cable of 2.5mm .
• Keep away from other electric cables or wires.

GROUND TERMINAL

NOTE
• The
power is in use. If use both at same time, be
sure not to exceed the total power for
(AC:1.6kVA, DC:5A)
• Most of motor appliances require more than
EARTH
their rated wattage, when starting.
MARK
receptacle can be used while the
DC
AC
and
AC
<<16>>