Konica Minolta ViZion DR+ 1417V2 Dealers Installation Manual
Konica Minolta ViZion DR+ 1417V2 Dealers Installation Manual

Konica Minolta ViZion DR+ 1417V2 Dealers Installation Manual

Wireless panel
Hide thumbs Also See for ViZion DR+ 1417V2:

Advertisement

Quick Links

ViZion DR+
1417V2
Wireless
Panel
Dealer
Installation
Manual
1

Advertisement

Table of Contents
loading

Summary of Contents for Konica Minolta ViZion DR+ 1417V2

  • Page 1 ViZion DR+ 1417V2 Wireless Panel Dealer Installation Manual...
  • Page 2: Table Of Contents

    ViZion DR+ 1417V2 Wireless Panel Hardware ..............5 Passive Installation ...................... 5 Integrated Installation ....................5 ViZion DR+ 1417V2 Wireless Panel Detector (Mars1417V2) ........6 G.I.P.S. Box (Generator Integration Power Supply) ............. 7 Synchronization, Ethernet and Power Cables .............. 7 ViZion DR+ Wireless Panel Battery Charger ..............
  • Page 3: Revision History

    [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] Revision History DATE DOCUMENT NAME [REASON FOR CHANGE] 6/27/2018 ViZion DR+ 1417V2 Wireless Panel Installation Manual [New Manual – iRay SDK Version 2 and Ultra version 4.2.9.0] Distributed by: Konica Minolta Healthcare Americas, Inc.
  • Page 4: Introduction

    This documentation is provided to you, the service technician, with all information necessary to install, configure and calibrate the ViZion DR+ 1417V2 Wireless Panel. For more detailed information on the operation and specifications of your wireless detector, please review the following documentation: Manual References: •...
  • Page 5: Hardware Overview And Installation

    Hardware Overview and Installation 1 ViZion DR+ 1417V2 Wireless 1.2 Integrated Installation Panel Hardware The following additional equipment is required The following equipment is required to properly for integration with a generator. install and implement your ViZion DR+ system. •...
  • Page 6: Vizion Dr+ 1417V2 Wireless Panel Detector (Mars1417V2)

    [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] D. Power button: Detector power ON/OFF 1.3 ViZion DR+ 1417V2 Wireless button Panel Detector (Mars1417V2) E. Infrared window: Infrared device sensor The following equipment is required for integration with a generator.
  • Page 7: Box (Generator Integration Power Supply)

    [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 1.5.1 Synchronization Cable 1.4 G.I.P.S. Box (Generator Integration Power Supply) Review the available signal wires in the following figures prior to connecting the generator synchronization cable. Note: depending on generator setup, you may need to cut off the DB9 end and wire directly.
  • Page 8: Vizion Dr+ Wireless Panel Battery Charger

    [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 1.6.1 Battery Charger Capacity Indicators 1.6 ViZion DR+ Wireless Panel Battery Charger 1.6.2 Connector Ports It is alternatively possible to trickle charge the battery inside the panel, by connecting the DC power cable from the DC medical adapter power supply to the DC input of the detector.
  • Page 9: Additional Components

    [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 1.7 Additional Components 2 Hardware Installation • Battery Pack (2) Now that you have verified the hardware, the next step is to connect all of the devices together. If you are uncertain whether or not...
  • Page 10: Mobile Hardware Installation

    [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 2.1.1 Connecting the Synchronization Cable 2.1.3 Connecting the Acquisition PC to the Wireless Access Point The power supply generator synchronization cable enables communication between the To connect the ASUS AP to the acquisition PC: ViZion DR+ wireless detector and the X-ray 1.
  • Page 11: Network Installation

    [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 2.2.2 SourceRay SR-130 Accessory Cables The following network equipment is required for fixed room environments: 1. Connect the hand switch cable to the • ASUS Dual-Band Wi-Fi Gigabit AP Generator Console (or directly to the tube head, depending on model X-ray unit being used).
  • Page 12: Mobile Network Configuration

    [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 3.1.1 Configure IP Address on the PC 3.2 Mobile Network Configuration For mobile environments, the panel can be put 1. From Control Panel, select Network into Client mode (to connect the laptop to an...
  • Page 13 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 1. From Control Panel, select Network Note: follow the instructions below Connections, and right-click on the Intel AFTER COMPLETING ALL STEPS in Local Area Network Ethernet adapter this installation manual. For now, leave and select Properties.
  • Page 14 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 3.2.2 ViZion DR+ 1417V2 Wireless Panel in 4. Enter the following settings: AP Mode (Alternative method) • IP address 192.168.8.188 • Subnet mask 255.255.255.0 When the panel is in AP mode you will connect to the panel’s broadcasted Wi-Fi network,...
  • Page 15: Software Installation And Configuration

    [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] Software Installation and Configuration 4 Software Installation 4.1 Install Microsoft Visual C++ Redistributable The ViZion DR+ 1417V2 panels require a prerequisite installation of Microsoft Visual C++ Redistributable for Visual Studio 2013, 4.
  • Page 16: Installation Of Ultra Software

    [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 4.2 Installation of Ultra Software 4.3 Configuration of Ultra Software All released versions of the Ultra installer files 1. Double-click on the Ultra icon to launch can be downloaded from the Konica Minolta the software.
  • Page 17 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 4.3.1 Activate Administrative Options 4.3.2 Create Technologists (Ultra Only) For DR technician support purposes, add a new 1. If this is a brand new install, the technologist for “Konica Minolta (KM)”. If you Configuration screen will have limited know the site technologist’s names, you can...
  • Page 18: Device Licensing

    Generation and select Third. licensing, contact Konica Minolta DR Support. 4.5 Device Driver Installation The ViZion DR+ 1417V2 wireless panel uses a different SDK version than 1417V panels, and it is only compatible with Ultra UAI versions 4.2.9.0 or higher, which introduces a selection for Third Generation Venu drivers.
  • Page 19 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 5. Click the Options icon in the top corner 9. After shutting down devices, check the of the Ultra Worklist screen. boxes for Download Driver and Install Driver next to Venu DR (in the middle of the Device Manager window).
  • Page 20 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 13. Click on I Agree. 16. Once completed you should verify that Venu installed. 14. Uncheck the box for “Automatically start the WinPcap driver at boot time” and then click Install.
  • Page 21: Device Pool Configuration

    [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 4. Scroll down to the Device section and 4.6 Device Pool Configuration click the button with 3 dots, to the right After successful driver pack installation, it is of “S/N” field. This will perform a scan...
  • Page 22: Idetector Interface

    [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 3. On the Detector tab, confirm that Trigger 4.7 iDetector Interface mode is set to TriggerMode_FreeSync. After clicking the Utility button under the If it is already set, skip to the next panel’s Device settings, the iDetector interface...
  • Page 23 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] Select 1 of the 2 following wireless methods: 4.7.3 Wi-Fi Configuration in AP Mode (Alternative connection method) 4.7.2 Wi-Fi Configuration in Client Mode 1. Within the Detector tab, click on the (Recommended connection method) Wifi tab and select AP mode.
  • Page 24 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 4.7.4 Panel Calibration Setup 3. Select the Calibrate tab, check the radio button for PostOffset, and click 1. Select the Acquire tab in iDetector. the Start Generate Templates button. 2. Uncheck the Defect, Gain, and Offset...
  • Page 25 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 6. Click Skip, in the top right corner, at the 8. Set your techniques to 70kV / 4.7 mAs Generator Parameter Learning screen and take your first exposure. 7. Click Skip, in the top right corner, at the Offset Calibration screen.
  • Page 26 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 11. After taking all 5 gain exposures, click 4.7.6 Panel Defect Calibration the Back button if you want to retake any previous exposures, then click Prep Note: the Defect Calibration screen and retake the exposure.
  • Page 27 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 14. If the exposure was NOT acceptable 17. If the exposure was acceptable, click (message in yellow), adjust mAs up or Next to move to the next frame. down, click the Prep button, and take another exposure.
  • Page 28 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 20. Set your techniques to 70kV / 7mAs 23. After taking all 19 defect exposures, and take your fourth exposure. click the Back button if you want to retake any previous exposures, then click Prep and retake the exposure.
  • Page 29 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 4.7.7 Download the Calibration Files to the 4. Browse to the Panel C:\opal\data\KGxxxxxxxxxxx\Correct \Default folder and select the After closing the Calibration window, you will be gain_2304x2800.gn file and click Open.
  • Page 30 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 7. Within the Calibrate tab, click on the 10. Browse to the Defect tab, then click the ReadStatus C:\opal\data\KGxxxxxxxxxxx\Correct button. \Default folder and select the defect_2304x2800.gn file. Click Open. Note: if the defect file does not appear, verify the file type dropdown is set to defect files(*.dft).
  • Page 31 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] 4.7.8 Re-enabling the Calibration Operation 4.7.9 Closing iDetector Options It’s important to close iDetector properly, in 13. Select the Acquire tab and check the order to sync the changes made in iDetector Offset, Gain and Defect checkboxes with Ultra UAI.
  • Page 32 [ViZion DR+ 1417V2 Wireless Panel Installation Manual] [Ultra 4.2.9.0] Note: if you configured the panel for Client mode, go back to Section 3.2.2 and follow the instructions for configuring the wireless adapter and installing the TP-Link AP. 1.800.366.5343 – Customer Support...