  • Page 1 ViZion DR+ 1417V2 Wireless Panel Calibration Manual...
  • Page 2: Table Of Contents

    ViZion DR+ 1417V2 Wireless Panel Hardware ..............5 Passive Installation ...................... 5 Integrated Installation ....................5 ViZion DR+ 1417V2 Wireless Panel Detector (Mars1417V2) ........6 ViZion DR+ Wireless Panel Battery Charger ..............7 Additional Components ....................8 Mobile Hardware Installation ..................8 Mobile Network Configuration ..................
  • Page 3: Revision History

    [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] Revision History DATE DOCUMENT NAME [REASON FOR CHANGE] 7/17/2018 ViZion DR+ 1417V2 Wireless Panel Calibration Manual [New Manual – iRay SDK Version 2 and Ultra version 4.2.9.0] Distributed by: Konica Minolta Healthcare Americas, Inc.
  • Page 4: Introduction

    This documentation is provided to you, the service technician, with all information necessary to install, configure and calibrate the ViZion DR+ 1417V2 Wireless Panel. For more detailed information on the operation and specifications of your wireless detector, please review the following documentation: Manual References: •...
  • Page 5: Hardware Overview And Installation

    Hardware Overview and Installation 1 ViZion DR+ 1417V2 Wireless 1.2 Integrated Installation Panel Hardware The following additional equipment is required The following equipment is required to properly for integration with a generator. install and implement your ViZion DR+ system. •...
  • Page 6: Vizion Dr+ 1417V2 Wireless Panel Detector (Mars1417V2)

    [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] D. Power button: Detector power ON/OFF 1.3 ViZion DR+ 1417V2 Wireless button Panel Detector (Mars1417V2) E. Infrared window: Infrared device sensor The following equipment is required for integration with a generator.
  • Page 7: Vizion Dr+ Wireless Panel Battery Charger

    [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] 1.4.1 Battery Charger Capacity Indicators 1.4 ViZion DR+ Wireless Panel Battery Charger 1.4.2 Connector Ports It is alternatively possible to trickle charge the battery inside the panel, by connecting the DC power cable from the DC medical adapter power supply to the DC input of the detector.
  • Page 8: Additional Components

    [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] 1.5 Additional Components 1.6 Mobile Hardware Installation • Additional required equipment for a mobile Battery Pack (2) environment. 1.6.1 SourceRay SR-130 Mobile X-Ray Unit • Side view • DC Medical Adapter for Detector and Battery Charger •...
  • Page 9: Mobile Network Configuration

    [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] 2. Make sure the mode switch on the 1.7 Mobile Network Configuration side of the access point is set to For mobile environments, the panel can be put AP/Rng Ext/Client. into Client mode (to connect the laptop to an...
  • Page 10: Vizion Dr+ 1417V2 Wireless Panel Hardware

    [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] 5. Scroll down to the Device section and 2 ViZion DR+ 1417V2 Wireless click on Utility to open the iDetector Panel Hardware interface. 2.1 Panel Calibration Before performing the following steps, make...
  • Page 11: Idetector Interface

    [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] 2.2.2 Panel Calibration Setup 2.2 iDetector Interface After clicking Utility under the panel’s Device 1. On the Acquire tab in iDetector, settings, the iDetector interface window will uncheck the Defect, Gain, and Offset open.
  • Page 12 [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] The Calibration wizard will open into a new 6. Click Skip, in the top right corner, at the window, presenting the Welcome screen. Generator Parameter Learning screen 3. Set X-ray environment: •...
  • Page 13 [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] 5. Wait for the Gain Map Generation to Note: after taking an exposure, the complete and then click Next, in the top current gain exposure frame will still right corner. be surrounded in green. It will either...
  • Page 14 [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] 2.2.4 Panel Defect Calibration (Optional) Note: after taking the first exposure, the A new defect map can be created by running current defect exposure frame will the Defect Calibration. A defect calibration is still be surrounded in green.
  • Page 15 [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] 5. Set your techniques to 40kV / 4mAs 8. If the exposure was acceptable, click and take your second exposure. Next to move to the next frame. 6. If the exposure was acceptable, click 9.
  • Page 16 [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] 11. Continue to take exposures with 13. Wait for the Defect Map Generation to techniques set to 70kV / 7mAs for the complete and then click Next. remaining frames (5-19). 14. Calibration is complete. Close the 12.
  • Page 17 [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] 2.2.5 Download the New Gain Calibration 4. Browse to the File to the Panel C:\opal\data\KGxxxxxxxxxxx\Correct \Default folder and select the After closing the Calibration window, you will be gain_2304x2800.gn file and click Open.
  • Page 18 [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] 2.2.6 Download the New Defect Calibration 4. Browse to the File to the Panel C:\opal\data\KGxxxxxxxxxxx\Correct \Default folder and select the If you ran the optional defect calibration, in defect_2304x2800.gn file. Click Open.
  • Page 19 [ViZion DR+ 1417V2 Wireless Panel Calibration Manual] [Ultra 4.2.9.0] 2.2.7 Re-enabling the Calibration Operation 2.2.8 Closing iDetector Options It’s important to close iDetector properly, in 1. Select the Acquire tab and check the order to sync the changes made in iDetector Offset, Gain and Defect checkboxes, with Ultra UAI.