Siemens DELTA i-system Technical Product Information page 6

Pushbutton wave shutter up 211
Hide thumbs Also See for DELTA i-system:

Advertisement

GAMMa wave
Technical Product Information
March 2008
DELTA i-system
Pushbutton wave shutter UP 211
DELTA profil
Pushbutton wave shutter UP 211
DELTA style
Pushbutton wave shutter UP 211
A shutter control insert sys equipped with a pushbutton
wave shutter can be operated via remote control by up
to 10 radio control pushbuttons (Diagram F).
1
2
3
10
Diagram F
If you wish shutter control insert I (G1 in Diagram G) to
be operated via remote control by pushbutton wave
shutter II (G3), the two pushbuttons wave shutter I and II
must be switched to the special function again. However,
the linking telegram has to be triggered at pushbutton
wave shutter II.
I
G1
G2
Diagram G
G1
Shutter control insert sys I
G2
Pushbutton wave shutter I
G3
Pushbutton wave shutter II
G4
Shutter control insert sys II
Technical Manual
Update: http://www.siemens.de/gamma
2.20.2.2/6
II
G4
G3
Pushbutton wave shutter UP 211, 7 pages
© Siemens AG 2008
Subject to change without prior notice
Procedure for deleting a connection:
Single connections can be deleted by assigning the new
correlation.
Deletion of the connection between the pushbutton
wave shutter in combination I and the shutter control
insert sys in combination II (Diagram D).
1.
Pushbutton wave shutter II: Switch to the special
function
2.
Pushbutton wave shutter I: Switch to the special
function
3.
Pushbutton wave shutter I: Trigger the linking tele-
gram
The connection between pushbutton wave shutter I and
shutter control insert II is thereby deleted.
Deleting all connections and resetting the supplied
state:
1. Switch the pushbutton wave shutter to the special
function.
Action: Press the pushbutton rocker in the CENTRE for at
least 10 seconds.
Display: The LED of the pushbutton begins to flash slowly
(approx. once per second) after 10 seconds
(toggling to the special function).
2. Reset the device.
Action: Press the pushbutton rocker again in the CENTRE
for at least 10 seconds.
Display: The LED of the pushbutton flashes rapidly (3
times per second) for approx. 3 seconds. The
LED is then extinguished and the pushbutton ex-
its the special function.
All connections are deleted. The device is restored to its
initial state.
Connections of this pushbutton wave shutter to other
inserts are retained and must likewise be deleted.