Gas conversion kits

Advertisement

Quick Links

General and Warnings
FOR YOUR SAFETY
— WHAT TO DO IF YOU
SMELL GAS
Do not try to light any
appliance.
Do not touch any
electrical switch; do not
use any phone in your
building.
Leave the building
immediately.
Immediately call your
gas supplier from a
phone remote from the
building. Follow the gas
supplier's instructions.
If you cannot reach your
gas supplier, call the
fire department.
— I
nstallation and service
must be performed by
a qualified installer,
service agency, or the
gas supplier.
The gas burner in this gas-fired equipment is designed and equipped to provide safe, complete
combustion. However, if the installation does not permit the burner to receive the proper supply of
combustion air, complete combustion may not occur. The result is incomplete combustion which
produces carbon monoxide, a poisonous gas that can cause death.
Safe operation of indirect-fired gas burning equipment requires a properly operating vent system
which vents all flue products to the outside atmosphere. FAILURE TO PROVIDE PROPER VENTING
WILL RESULT IN A HEALTH HAZARD WHICH COULD CAUSE SERIOUS PERSONAL INJURY OR
DEATH.
If installed as a separated-combustion system, install either the horizontal or vertical combustion
air/vent system illustrated in the heater installation manual, using the concentric adapter supplied.
All installations must comply with the combustion air requirements in the installation codes and
instructions. Units installed in a confined space must be supplied with air for combustion and
ventilation as required by Code and in the heater installation manual. Combustion air at the burner
should be regulated only by manufacturer-provided equipment. NEVER RESTRICT OR OTHERWISE
ALTER THE SUPPLY OF COMBUSTION AIR TO ANY HEATER. MAINTAIN THE VENT SYSTEM IN
PROPERLY OPERATING CONDITION.
Gas Conversion Kits and Instructions
The conversion kit is to be selected and installed by a qualified
service person in accordance with these instructions and
in compliance with all codes and requirements of authorities
having jurisdiction. Failure to follow instructions could result
in death, serious injury and/or property damage. The qualified
agency performing this work assumes responsibility for this
conversion.
In Canada, gas conversion shall be carried out in accordance with the
requirements of the Provincial Authorities having jurisdiction and in
accordance with the requirements of CSA-B149.1 and .2 installation
code.
Improper installation, adjustment, alteration, service, or
maintenance can cause property damage, injury, or death.
Read the installation, operation, and maintenance instructions
thoroughly before installing or servicing this equipment.
FOR YOUR SAFETY: Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any
other appliance.
HAZARD INTENSITY LEVELS used in this manual.
1. DANGER: Failure to comply will result in severe personal injury or
death and/or property damage.
2. WARNING: Failure to comply could result in severe personal
injury or death and/or property damage.
3. CAUTION: Failure to comply could result in minor personal injury
and/or property damage.
DANGER:
DANGER
Form CP-CAUA-GC (01-18)
Obsoletes CP-CAUA-GC (04-15)
Applies to: Model CAUA
DANGER:
WARNING
Form CP-CAUA-GC, P/N 170635R9, Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the CAUA Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Reznor CAUA Series

  • Page 1 Form CP-CAUA-GC (01-18) Obsoletes CP-CAUA-GC (04-15) Gas Conversion Kits and Instructions Applies to: Model CAUA General and Warnings DANGER: The conversion kit is to be selected and installed by a qualified FOR YOUR SAFETY service person in accordance with these instructions and —...
  • Page 2: Gas Conversion Instructions

    Description and The gas conversion kits in these instructions are for Model CAUA heaters equipped with specific single-stage or two-stage valves (see NOTE left). The kits are for opera- Kit Selection tion at sea level. See pages 5-6 for conversion kit application and components. See page 7 for high altitude burner orifices.
  • Page 3 To install a regulator spring conversion kit, follow the valve manufacturer's installation instructions that are included with the regulator spring kit. After a new spring kit is installed, it is necessary to adjust the spring for the correct manifold pressure. This adjustment can only be made after the heater is in operation. Instructions are in Step No.
  • Page 4: Gas Conversion

    Gas Conversion 7. Measure the Manifold Pressure (cont'd) Instructions WARNING (cont'd) Manifold gas pressure must never exceed 3.5" w.c. for natural gas or 10" w.c. for propane. Instructions for Measuring and Adjusting Manifold Pressure: 1) Locate the 1/8” outlet pressure tap on the valve. Turn the knob on the top of the valve to “OFF”.
  • Page 5 Components - The burner orifices in these kits are for sea-level operation only. (For high altitude installation (above 2000 ft), see the Burner Orifice Chart on page 7.) All kits include Natural to Propane the quantity of orifices required for the largest size of heater. Excess parts may not be Conversion Kits returned for credit.
  • Page 6 Components - The burner orifices in these kits are for sea-level operation only. (For high altitude installation (above 2000 ft), see the Burner Orifice Chart on page 7.) Propane to Natural All kits include the quantity of orifices required for the largest size of heater. Excess Conversion Kits burner orifices may not be returned for credit.
  • Page 7: Burner Orifices

    Burner Orifice Chart - Model CAUA Model CAUA BURNER ORIFICES Quantity The gas conversion kits on Natural Gas, 0-2000 ft, P/N 164866 11833 11833 11833 11835 45870 pages 5 and 6 include the installation in U.S. or Canada standard sea level burner Size 2.1mm (orifices in the conversion kits) orifices listed as 0-2000 ft in...
  • Page 8 Gas Conversion - Applies only to Model CAUA with 2-Stage White-Rodgers Valve (Serial No. Codes H5, H6, M9) NOTE: See example on page 2 for decoding the serial number. Components required to convert a Model CAUA with a 2-stage White-Rodgers valve: □...

This manual is also suitable for:

Caua 150Caua 300Caua 200Caua 350Caua 250Caua 400