SSANGYONG KYRON 2005.10 Manual page 414

Table of Contents

Advertisement

OVERVIEW AND OPERATION PROCESS
1. ALARM INTERVAL OF PARKING AID SYSTEM
Alarm interval and display changes according to the distance as below:
While reversing, if obstacles are within stage 1, the warning beep sounds with long intervals. If
within stage 2, the warning beep sounds with short intervals and if within stage 3, the warning
beep sounds continuously.
2. TROUBLESHOOTING OF SENSOR
When the power is applied (gear selector lever is in "R" position), the sensor will be diagnosed
once. If found any failure due to open circuit to sensor or communication error, warning buzzer
sounds for 3 seconds and the data on failed sensor transmits to the instrument panel to light up
the corresponding LED.
If normal, the warning buzzer sounds only for 65 ms.
Whenever the power is applied, the
diagnosis mode is initiated.
Sensor failure conditions
(conditions for warning beep due to failure)
-
Sensor failure conditions
(conditions for warning beep due tofailure)
-
Open in sending circuit
-
Open in receiving circuit
-
Open in power circuit (+, -)
▶ Warning beeps
Back sonar (RH)
Back sonar (center)
10-7
8790-03
Back sonar (LH)
PAS
KYRON 2005.10