SSANGYONG KYRON 2005.10 Manual page 120

Table of Contents

Advertisement

VGT Turbocharger
Vacuum
modulator
To exhaust
pipe (DOC)
Exhaust
manifold
PCV Oil Separator
Cylinder head cover (oil + gas)
Inlet port
The first separation will happen when blow-
by gas passes through baffle plates in
cylinder head cover. Then oil and gas will
be separated due to cyclone effect after
entering the oil separator inlet port.
Separated oil returns to oil pan via oil drain
port and the gas will be burnt again after
entering the combustion chamber through
air
duct
hose
via
opens/closes due to pressure differences
between the intake side and crankcase.
Blow-by gas
(air duct hose)
Oil
(oil gauge pipe)
PCV
valve
that
EGR Valved
Intake com -
pressed air
Exhaust gas
Turbocharger Vacuum Modulator
Turbo -
charger
actuator
IP interior fuse
box (RH)
No.63(7.5A)
01-15
0000-00
Vacuum
pump
Engine ECU
(No. 95)
ENGINE GENERAL
KYRON 2005.10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents